5.10.2 Changing a Setting
Depending on the menu item, alter settings by using these methods. When the instruction reads
PRESS to Alter,
you have the option to exit the editing mode to review the settings.
Numeric-Entry Method
With this method you change settings by entering a decimal or hexadecimal number, digit-by-digit.
The LCD shows the instruction
PRESS to Incremnt
the alterable digit. The highlighted digit is
incremented by pressing the mode switch. If no switch activity occurs for four seconds, the next digit
to the right is highlight. When the highlight proceeds past the rightmost digit, the display shows
PRESS if Done
, allowing you to confirm the changes. If the numerical value requires additional
editing, do not press the mode switch. Wait until the highlight restarts at the leftmost digit and then
continue editing the setting.
SCSI ID:
[00]
PRESS to
Alter
SCSI ID:
[01]
PRESS if
Done
SCSI ID:
[01]
PRESS to
Incremnt
Figure 26
Numeric entry example
Pick-Entry Method
This method of configuration allows you to select from a predefined list of items. When
PRESS to
Scroll
appears on the LCD, you can view the list of items by repeatedly pressing the mode switch.
When the switch is inactive for four seconds, the instruction
PRESS if Done
appears to allow
you to confirm the setting. To change the setting, wait until the
PRESS to Scroll
instruction
appears on the LCD and continue editing.
BaudRate
9600 bps
PRESS to
Scroll
BaudRate
1200 bps
PRESS to
Scroll
BaudRate
9600 bps
PRESS to
Alter
BaudRate
19K2 bps
PRESS if
Done
BaudRate
2400 bps
PRESS to
Scroll
Figure 27
Pick entry example