beautypg.com

Hp sum supported firmware for hp proliant servers – HP Integrity rx2800 i2 Server User Manual

Page 18

background image

Introduction 18

HP SUM stores host and group information from session to session. However, user names, passwords, and

existing credentials are not stored in a session or from session to session.
Use OA version 2.51 or later to get a list of all major firmware versions deployed in your enclosure, using the

Rack Firmware link on the main OA web page. HP supports the current and two previous versions of the HP

Smart Update Firmware DVD.

NOTE:

The Onboard Administrator and Virtual Connect Ethernet and Fibre Channel Modules

are supported only in online deployments on HP ProLiant servers.

NOTE:

You can add firmware components to the USB drive key in the /hp/swpackages

directory.

IMPORTANT:

Before deploying firmware updates to a target server, be sure that a recent backup

of the target server is available in the event the deployment procedure fails.

For more information about deploying firmware on HP ProLiant servers, see the HP Smart Update Firmware

DVD User Guide on the HP website

(

http://h20000.www2.hp.com/bizsupport/TechSupport/DocumentIndex.jsp?contentType=SupportManu

al&lang=en&cc=us&docIndexId=64179&taskId=101&prodTypeId=18964&prodSeriesId=345557

).

NOTE:

Currently, HP SUM cannot be used to deploy firmware on HP Integrity servers except for

HP Integrity BL860c/BL870c/BL890c i2 Servers.

HP SUM supported firmware for HP ProLiant servers

Component

Supported

HP ProLiant ML/DL/SL series System ROM

Yes

HP Workstation WS460c G6 Blade ROM

Yes, offline only

HP ProLiant Blade Servers ROM

Yes

HP ProLiant 100-series Servers ROM

Yes

iLO 2 firmware

Yes, local and remote

iLO 3 firmware

3

Yes, local and remote

LO-100 firmware

3

Yes

Broadcom NIC firmware

Yes

Intel® NIC firmware

No

QLogic NIC firmware

Yes, offline only

Mellanox NIC firmware

Yes

Power Management Controller firmware

Yes

Smart Array Controller firmware

Yes

SAS and SATA hard drive firmware behind Smart Array controllers Yes

SAS and SATA hard drive firmware behind non-Smart Array

controllers

No