Deployment from hp sum, Executing hp sum – HP Integrity rx2800 i2 Server User Manual
Page 14
Introduction 14
HP SUM
version
Delivered with
Support and limitations
4.1.1
•
HP ProLiant Support Pack for Linux 8.62
•
No support for BL860c/BL870c/BL890c i2
Servers firmware or HP Integrity Support Pack
4.2.0
•
HP ProLiant Support Pack for Linux 8.70
•
HP ProLiant Support Pack for Windows®
8.70
•
No support for BL860c/BL870c/BL890c i2
Servers firmware or HP Integrity Support Pack
4.2.1
•
HP Smart Update Firmware DVD 9.30
•
No support for BL860c/BL870c/BL890c i2
Servers firmware or HP Integrity Support Pack
Deployment from HP SUM
The following sections discuss deployment from HP SUM.
Executing HP SUM
HP SUM provides three modes of execution for users:
•
GUI—For firmware and software deployments
•
Express—For software deployments only (local host only)
•
Scripted—For firmware and software deployments running silently
HP SUM enables you to deploy to both local and remote deployments. HP SUM can run in both standard
Windows® and Linux operating systems in online mode and in offline mode (available on HP Smart Update
Firmware DVD) through special boot environments based on Linux boot kernels as long as the prerequisites
are met.
Use the following table to determine the correct execution mode for the server use case.
IMPORTANT:
Before deploying software updates to a target server, be sure that a recent backup
of the target server is available in the event the deployment procedure fails.
Scenario
Description
HP SUM command HP deliverable
Interactive, graphical
deployment on a local
host (Run HP SUM on the
server being updated.)
Use this scenario when you:
•
Are not familiar with
command line tools
•
Are deploying
components on a local,
single host
•
Do not require scripting
•
Want to select the
components to be
installed
•
Windows®:
hpsum
•
Linux:
./hpsum
•
Online:
HP ProLiant Support Pack for
Windows® and Linux
or
Smart Update Firmware DVD
•
Offline:
Smart Update Firmware DVD
Scripted deployment on a
local host (Run HP SUM
from a network share on a
local server.)
Use this scenario when you:
•
Are familiar with
command line tools
•
Are deploying
components on a local,
single host
•
Must perform a
customized, scripted
•
Windows®:
hpsum -s
•
Linux:
./hpsum -s
•
Online:
HP ProLiant Support Pack for
Windows® and Linux
or
Smart Update Firmware DVD
or
HP Integrity Support Pack for
- Integrity rx3600 Server SmartStart-Software Integrity BL860c Server-Blade Integrity rx2660 Servers Smart Update Manager Service Pack for ProLiant Integrity rx6600 Server Integrity rx8640 Server Integrity rx7640 Server Integrity BL870c Server-Blade Integrity Superdome sx2000 Server Integrity BL860c i2 Server-Blade Integrity BL870c i2 Server-Blade