Multiple-host installations – HP Integrity rx2800 i2 Server User Manual
Page 46
HP SUM User Interface 46
NOTE:
After updating hard drives in external enclosures such as MSA20, you must power cycle
the external enclosures. The Reboot button in HP Smart Update Manager only reboots the server
but never power cycles an external enclosure.
The following installation logs contain information about the installation activity for each host being updated:
•
hpsum_log.txt log—Contains a brief summary of the installation activity
•
hpsum_detail_log.txt log—Contains all of the installation details, including errors, for each component
installed
The log files can be found in the following locations:
•
For Windows® operating systems, these files are located in subdirectories named according to the IP
address of each host in the \CPQSYSTEM\hp\log subdirectory on the boot partition of the local host.
The directory containing the local host information is named localhost instead of being named after
the IP address.
•
For Linux operating systems, these files are located in subdirectories named according to the IP address
of each host in the /var/hp/log subdirectory of the local host. The directory containing the local host
information is named localhost instead of being named after the IP address.
A new file contains detailed information on the execution of HP SUM.
•
For Windows® operating systems, the filename is:
C:\cpqsystem\hp\log\hpsum_execution_log_
•
For Linux operating systems, the filename is:
/var/hp/log/hpsum_execution_log_
NOTE:
Using the offline environments provided by the HP Smart Update Firmware DVD and HP
BladeSystem Firmware Deployment Tool results in the log files being written to the Linux location.
HP SUM also creates trace logs of its installation that can be used to debug problems. These trace files are
located in the following places:
•
For Windows Server® 2003, Windows® XP, and Windows Vista®—%TEMP%\hp_sum\
•
For Windows Server® 2008 and Windows Server® 2011 Small Business and 2011 SBS
Essentials—%TEMP%\
•
For Linux—/tmp/hp_sum
HP SUM creates a separate trace log for each target server. These logs are captured in subdirectories under
the trace log directories. The directories start with Target_0, Target_1, and so forth. These contain the target
specific trace information. No passwords or sensitive data is stored in this trace logs.
Multiple-host installations
HP SUM provides simultaneous firmware and software deployment for multiple ProLiant remote targets and
options in both GUI and CLI modes. For performance and optimization, if more than 20 remote targets exist
for simultaneous update, HP SUM starts with the update for the first 20 targets and when each target update
completes, then the next target in line is selected until all targets have been updated.
After you start HP SUM, the Source Selection screen ("
Selecting the location to check for updates
" on page
) appears, enabling you to specify where to find the components that you want to deploy. After selecting
the component's location ("
Selecting the location to check for updates
" on page
), the Inventory Progress
- Integrity rx3600 Server SmartStart-Software Integrity BL860c Server-Blade Integrity rx2660 Servers Smart Update Manager Service Pack for ProLiant Integrity rx6600 Server Integrity rx8640 Server Integrity rx7640 Server Integrity BL870c Server-Blade Integrity Superdome sx2000 Server Integrity BL860c i2 Server-Blade Integrity BL870c i2 Server-Blade