Command-line examples – HP Integrity rx2800 i2 Server User Manual
Page 72
Scripted deployment 72
Command-line argument Description
the same directory as the HP SUM log files.
Including other arguments on the command line can modify the contents of the
report. Using the /target argument will allow reports to be generated for
different targets.
(This CLI does not apply to firmware updates on the HP Integrity
BL860c/BL870c/BL890c i2 Servers.)
Using input files
/inputfile “filename”
This argument enables you to script the deployment of firmware and software to
multiple remote systems at one time. For details of the file format and commands,
)".
/deleteinputfile
“filename”
This argument enables you to instruct HP SUM to delete the input file after it has
been read in.
Component configuration for Windows components only
To configure components without using the HP Smart Update Manager GUI, issue the command,
hpsum_config
in the HP Smart Update Manager GUI. You must run this command from a CD or other read-only media, or
the component cannot be configured. Configuration for a given component only needs to be executed one
time. The configuration is stored within the component and is propagated to all target servers when deployed
through HP Smart Update Manager GUI or command line. To change the configuration, rerun
hpsum_config against the component and a new configuration writes out. If a component does not need
configuration, the hpsum_config command returns to the console.
To configure components to be deployed on all editions of the Windows Server® 2008 with the Server Core
option, you must access the system as a remote host using HP Smart Update Manager running on a system
with a supported Windows® operating system, and then configure the components before deployment.
Command-line examples
The following command-line parameter examples can be executed within these environments:
•
Windows® PSPs:
o
ProLiant Support Pack for Microsoft® Windows Server™ 2003 v7.90 (BP000323.xml)
o
ProLiant Support Pack for Microsoft® Windows Server™ 2003 v7.80 (BP000315.xml)
•
Firmware:
o
System ROM
o
Smart Array controller
o
Hard drives
o
iLO
•
Software—later version of:
o
HP Insight Diagnostics Online Edition for Windows Server™ 2003 (cp008097.exe)
o
HP System Management Homepage for Windows® (cp008257.exe)
•
HP Smart Update Manager
- Integrity rx3600 Server SmartStart-Software Integrity BL860c Server-Blade Integrity rx2660 Servers Smart Update Manager Service Pack for ProLiant Integrity rx6600 Server Integrity rx8640 Server Integrity rx7640 Server Integrity BL870c Server-Blade Integrity Superdome sx2000 Server Integrity BL860c i2 Server-Blade Integrity BL870c i2 Server-Blade