Command-line examples – HP Integrity rx2800 i2 Server User Manual

Page 72

background image

Scripted deployment 72

Command-line argument Description

the same directory as the HP SUM log files.

Including other arguments on the command line can modify the contents of the
report. Using the /target argument will allow reports to be generated for

different targets.
(This CLI does not apply to firmware updates on the HP Integrity

BL860c/BL870c/BL890c i2 Servers.)

Using input files

/inputfile “filename”

This argument enables you to script the deployment of firmware and software to

multiple remote systems at one time. For details of the file format and commands,

see "Input files (on page

75

)".

/deleteinputfile

“filename”

This argument enables you to instruct HP SUM to delete the input file after it has
been read in.

Component configuration for Windows components only

To configure components without using the HP Smart Update Manager GUI, issue the command,
hpsum_config . This command presents the same configuration screens seen

in the HP Smart Update Manager GUI. You must run this command from a CD or other read-only media, or
the component cannot be configured. Configuration for a given component only needs to be executed one

time. The configuration is stored within the component and is propagated to all target servers when deployed

through HP Smart Update Manager GUI or command line. To change the configuration, rerun
hpsum_config against the component and a new configuration writes out. If a component does not need

configuration, the hpsum_config command returns to the console.
To configure components to be deployed on all editions of the Windows Server® 2008 with the Server Core

option, you must access the system as a remote host using HP Smart Update Manager running on a system

with a supported Windows® operating system, and then configure the components before deployment.

Command-line examples

The following command-line parameter examples can be executed within these environments:

Windows® PSPs:

o

ProLiant Support Pack for Microsoft® Windows Server™ 2003 v7.90 (BP000323.xml)

o

ProLiant Support Pack for Microsoft® Windows Server™ 2003 v7.80 (BP000315.xml)

Firmware:

o

System ROM

o

Smart Array controller

o

Hard drives

o

iLO

Software—later version of:

o

HP Insight Diagnostics Online Edition for Windows Server™ 2003 (cp008097.exe)

o

HP System Management Homepage for Windows® (cp008257.exe)

HP Smart Update Manager