background image

Scripted deployment 66

Scripted deployment

Command-line interface

The HP SUM command-line interface enables you to script custom installations.

Command-line syntax

The general command-line syntax for HP SUM is:

hpsum [/h[elp]] [/?] [/f[orce]] [/f[orce]:bundle] [/f[orce]:rom]

[/f[orce]:software] [/f[orce]:all ] [/g (/downgrade)] [/e (/rewrite)]

[/m[utual])] [/c[omponent] ] [/s[ilent]]

[/allow_update_to_bundle] [/allow_non_bundle_components] [/b[undle]

] [/express_install] [/use_snmp] [/use_location

"file_share"] [/use_web] [use_proxy] [proxy_server] [/use_d[ownloaded]*]

[/tpmbypass] [/ignore_tpm] [/use_wmi] [/use_latest] [/romonly]

[/softwareonly] [/continue_on_error ]

[/override_existing_connection] [/On_failed_dependency:]

[/r[eboot]] [/reboot_message "reboot message"] [/reboot_delay

timeout_in_seconds] [/reboot_always] [/dryrun] user or /username

] [/passwd ] [/current_credential] [/target

"netAddress"] [/group "group_name"] [/ [/logdir "path"] [/v[erbose]]

[/veryv[erbose]] [/report] [/inventory_report] [/firmware_report]

[/inputfile "filename"] [/deleteinputfile

"filename"][ ...]

[ ...]

HP SUM with Onboard Administrator requires a user ID and password to log in. The user ID must be an

Administrator equivalent ID and not an operator or user equivalent level ID.

NOTE:

All arguments and information enclosed in brackets are optional. The arguments may be

prefixed with either a '-' or '/' character. These examples show only the '/'.

On Windows® operating systems, use a slash (/) before each argument. On Linux operating systems, use a

hyphen (-) before each argument.
If the /s[ilent] argument is not included on the command line, the HP SUM GUI appears.

NOTE:

Command line syntax does not support double-byte character sets. Any messages

entered through the command line using a double-byte character set will not be displayed
correctly.

NOTE:

When using HP SUM with HP Integrity BL860c/BL870c/BL890c i2 Server bundles, HP

SUM does not have any command-line arguments to specify the Upload and Do Not activate
option. If HP SUM is started from the command line using the silent argument (/s[ilent]), then

the system being updated reboots automatically. Also, no reporting functionality using CLI is

available when using HP SUM for firmware updates on these servers.