beautypg.com

Suggested action – HP Insight Foundation Software for ProLiant User Manual

Page 70

background image

to eject the boot CD and as a result, after the reboot, the VM will boot back into the boot CD. This
issue is specific to Microsoft Hyper-V VMs.

Suggested action

Manually eject the virtual boot CD from the VM and reboot the VM.

Operating system is not booting on a destination server that has SAN disks

After you perform a successful P2P migration of the SLES 11 SP1 32-bit operating system on SAN
disks with Brocade or QLogic Fibre Channel HBA as the primary boot controller, the operating
system does not boot on the destination server.

Suggested action

Before you migrate any Linux distribution to a destination server that has SAN storage, make sure
that the RPM package containing firmware files (such as
brocade-firmware-.noarch.rpm

and

qlogic-firmware-.noarch.rpm

on SLES OS, and

ql2xxx-firmware-.noarch.rpm

on RHEL OS) for the target SAN Fibre Channel

HBA are installed on the source server from the OS installation media.

Post Migration of SLES 11 SP3 OS boot up takes long time on destination server with
Brocade 82B or 41B or SN1000Q FC card

After performing successful migration of SLES 11 SP3 32–bit and 64–bit operating systems on a
destination server configured with Brocade 82B or 41B or SN1000Q FC card, the operating
system takes long time to boot.

Suggested action

Operating System may take around 30 minutes to boot.

Error is displayed for a missing file system while migrated Linux OS is booted on the
destination server

When you migrate a file system to the destination server multiple times, the multiple file systems
that contain the same UUID are created.

Suggested action

Make sure that multipath is configured on the source server. If multipath is not configured, make
sure that the file systems that are being migrated do not have the same UUID.

Logical drives of HP Smart Array B110i SATA RAID Controller are removed

After a successful X2P migration of the Windows Server 2008 OS, the logical drives of HP Smart
Array B110i SATA RAID Controller are removed.

Suggested action

When the logical drives are removed, you must re-create the exact logical drives by using ACU
or ORCA on the destination server after migration.

Unable to download the log files from the migration wizard when using IE 9

While using IE 9, you are unable to download the log files from the migration wizard.

Suggested action

Perform the following steps:
1.

From the IE 9 browser, click Tools

→Internet Options.