Suggested action, Migration process – HP Insight Foundation Software for ProLiant User Manual
Page 59
Suggested action
Before you migrate, you must disable the AMD virtualization or Intel Hyper-Threading in the BIOS
of the destination server.
Migration process
Drivers cannot be installed or injected onto a boot disk
This error is reported if Insight Control fails to install or inject device drivers. In most cases, additional
information is reported on the destination server.
Suggested action
Possible causes and solutions for this error include:
•
The boot partition was not migrated to the boot volume on the destination server. Verify that
the boot partition is selected for migration and placed on the boot volume of the destination
server.
•
The network connection failed during driver installation.
•
The destination server failed or was powered down during driver installation.
•
The storage controller where the boot partition was placed is not supported. For a complete
list of supported controllers, see HP Insight Management Support Matrix at
.
•
The iSCSI initiator failed to mount the disk. To resolve this issue, perform the following steps:
1.
Clear the stale iSCSI session.
2.
Restart iSCSI services.
3.
Restart the server migration service, if required.
Migrating a Linux source server that has large storage fails when the migration is
initiated
Migrating a Linux source server that has large storage might fail with the following error found in
the
hpsmpsvc.log
file:
java.lang.OutOfMemoryError: Java heap space
Suggested action
Increase the heap size on the source server, by performing the following:
1.
Ensure that the source agent is not running.
2.
Change the current working directory on the source server to the smpagent folder (for example,
/root/smpagent
if the agent was automatically deployed).
3.
Increase the initial memory by changing the following parameters in /bin/hpvmmsmp.conf:
# Initial Java Heap Size (in MB)
wrapper.java.initmemory=512
# Maximum Java Heap Size (in MB)
wrapper.java.maxmemory=1024
4.
Start the server migration Source Agent by doing one of the following at the command line:
•
Type ./startHPSMPCnt.sh and then press Enter.
•
Navigate to the smpagent/bin directory and then run the startHPSMPCnt.sh script.
Migration process
59