Interface specification, Environmental specification, Vibration and shock tolerance – HP Surestore DLT 80 Tape Drive User Manual
Page 68
![background image](/manuals/396831/68/background.png)
Product Specifications and Ordering Information
Product Specification
A-3
Interface Specification
Environmental Specification
See page 4-5 for advice on using and storing cartridges.
Operating Limits
Non-operating Limits
Cooling (HP SureStore DLT 40i, 70i and 80i only)
Requires air flow of 0.635 m/s (125 linear feet per minute). The
measurement is taken at the front grill under the handle. Air flow should
be from front to back.
Vibration and Shock Tolerance
Operating Vibration
HP SureStore DLT 40
:
Narrow single-ended SCSI-2 (8-bit wide data transfers
with parity)
HP SureStore DLT 70
:
Fast, wide single-ended SCSI-2 (16-bit wide data
transfers with parity)
HP SureStore DLT 80
:
Ultra-wide SCSI-2 (16-bit wide data transfers), which can
be used with both LVD (low-voltage differential) and
single-ended host bus adapters.
Temperature: 10°C to 40° C (50°F to 104°F)
Humidity:
20% to 80% non-condensing
Altitude:
0 m to 9 km (0 to 30,000 ft)
Temperature:
−
40°C to 66° C (
−
40°F to 151°F)
Humidity:
10% to 95% non-condensing
Altitude:
0 m to 15 km (0 to 50,000 ft)
Vibration Type
Sine
Sweep
Frequency Range:
5–500–5 Hz
Upward and downward
Acceleration Level: 0.25g
0.010” DA
22 to 500 Hz
5 to 22 Hz (crossover)
Application:
X, Y and Z axes
Sweep rate: 1 octave per minute