Product Specifications and Ordering Information

Product Specification

A-3

Interface Specification

Environmental Specification

See page 4-5 for advice on using and storing cartridges.

Operating Limits

Non-operating Limits

Cooling (HP SureStore DLT 40i, 70i and 80i only)

Requires air flow of 0.635 m/s (125 linear feet per minute). The
measurement is taken at the front grill under the handle. Air flow should
be from front to back.

Vibration and Shock Tolerance

Operating Vibration

HP SureStore DLT 40
:

Narrow single-ended SCSI-2 (8-bit wide data transfers
with parity)

HP SureStore DLT 70
:

Fast, wide single-ended SCSI-2 (16-bit wide data
transfers with parity)

HP SureStore DLT 80
:

Ultra-wide SCSI-2 (16-bit wide data transfers), which can
be used with both LVD (low-voltage differential) and
single-ended host bus adapters.

Temperature: 10°C to 40° C (50°F to 104°F)

Humidity:

20% to 80% non-condensing

Altitude:

0 m to 9 km (0 to 30,000 ft)

Temperature:

40°C to 66° C (

40°F to 151°F)

Humidity:

10% to 95% non-condensing

Altitude:

0 m to 15 km (0 to 50,000 ft)

Vibration Type

Sine

Sweep

Frequency Range:

5–500–5 Hz

Upward and downward

Acceleration Level: 0.25g

0.010” DA

22 to 500 Hz
5 to 22 Hz (crossover)

Application:

X, Y and Z axes

Sweep rate: 1 octave per minute