Page 24: G + {s} + {n} + {d1} + ... + {dn, 67 h + {s} + {n} + {d1} + ... + {dn, Description, S 0x0: data transmission, 0x1~0xfe: not used, N=90 (ql-500/550/560/570/580n/650td/700), N=162 (ql-1050/1060n)

background image

Name

Raster graphics transfer

Syntax

g + {s} + {n} + {d1} + ... + {dn}

67 H + {s} + {n} + {d1} + ... + {dn}

Description

{s} The definition of raster information s is as follows.

s 0x0: Data transmission

0x1~0xFE: Not

used

0xFF:

Indicates that data transmission should be stopped.

{n} Transfers the specified number of bytes (n) of data. (However, this changes if the

data is compressed using the serial interface.)

n=90 (QL-500/550/560/570/580N/650TD/700)

n=162 (QL-1050/1060N)

{d1-dn} Print data.

Name

Zero raster graphics

Syntax

Z

5A H

Description

Raster line is filled in zero data. (Compression mode)

Name

Print command

Syntax

FF

0C H

Description

Used as a print command, except for the last label when multiple labels are printed.

Name

Print command with feeding

Syntax

Control-Z

1A H

Description

Used as a print command for the last label when multiple labels are printed.

Name

Baud rate setting (QL-580N/650TD/1050/1060N)

Syntax

ESC + i + B + {n1} + {n2}

1B H + 69 H + 42H + {n1} + {n2}

Description

This changes the communications baud rate for the main unit. The factory setting is

115200 bps

Definition of {n1} and {n2}

Setting = n1 + n2 * 256

Setting: 96=9600 bps, 576=57600 bps, 1152=115200 bps