Periodic Checks
Every Six Months
Inspect all electrical connections for secure attachment and for safe 
and secure ground connections. Inspect the power cable, especially 
at the entrance point to the unit. This inspection should be made by 
a qualified electrician. Check for leaks, especially under the pump, 
as it may indicate a worn pump seal. 
 
 
6-2 Corrective
Maintenance
Pumps and Seals
Before leaving our factory, we test each unit extensively, then we 
calibrate each unit. Afterwards, the unit is drained and blown out 
with air to remove water from piping systems. If the unit is 
allowed to stand idle for a long time before being installed in your 
factory, the housing gasket at the pump can dry out and can 
possibly leak when the unit is started. In most cases these gaskets 
will soon swell and form a tight seal. In other cases, it may be 
necessary for you to tighten the pump bolts to stop a leaking 
condition. 
Pump seal surfaces can separate slightly because of rough handling 
or from vibration during transit. This could cause a leak at the 
pump seal when the pump is started, but in most cases the surfaces 
will mate again after the pump is allowed to run for a short period 
of time. If they do not reseal, you may need to open the pump and 
free the seal by hand. It is seldom necessary to install a 
replacement seal in a new unit unless the seal has been damaged 
because the unit was started without water. 
Our pump seals have a long period of service life. Some 
conditions, of course, can shorten seal life, including the presence 
of grit, operation of the unit without water, sustained high water 
temperature, or presence of certain chemicals in the water. Our 
pump seal assembly has been developed to resist abrasive particles 
that are present in many water systems. This is done by a special 
flushing system that uses water exiting the pump to constantly 
wash the seal area. 