Figure 3 royal series unit full-load amps – Sterlco Royal Series Compact Temperature Control Unit User Manual
Page 11
Royal Series Water Temperature Control Units
Page 11
Figure 2
Typical Royal Upright Series Water Temperature Control Unit and Specifications
48"
3 3/4"
28"
13"
Model
Dimensions
Shipping
number Pump
H W
D
weight
460 230 letter hp kW
gpm
lpm
psig
kPa
in.
cm in. cm in. cm lbs.
Kg
C ¾
0.56
30
113.6
25
172.4
D 1 0.75
35
132.5
30
206.9
F 2 1.50
50
189.3
30
206.9
G 3
2.24
60
227.1
35
241.3
210
96
H 5 3.73
75
283.9
54
372.3
J 7½ 5.60
90
340.7
63
434.4
240
109
2012,
9 kW heater
K 10
7.46
120
454.2
55
379.2
48
122
13 33 28 71.1
270
123
Figure 3
Royal Series Unit Full-Load Amps
Model
Full-load amps at 460 volts
hp
kW
9 kW heater
12 kW heater
18 kW heater
24 kW heater
36 kW heater 48 kW heater
0.75 hp 0.56 kW
12.7 amps
16.5 amps
24.0 amps
31.6 amps
47.4 amps
62.4 amps
1.00 hp 0.75 kW
13.1 amps
16.9 amps
24.4 amps
32.0 amps
47.8 amps
62.8 amps
2.00 hp 1.50 kW
14.7 amps
18.5 amps
26.0 amps
33.6 amps
49.4 amps
64.4 amps
3.00 hp 2.24 kW
16.1 amps
19.9 amps
27.4 amps
35.0 amps
50.8 amps
65.8 amps
5.00 hp 3.73 kW
18.9 amps
22.7 amps
30.2 amps
37.8 amps
56.6 amps
71.6 amps
7.50 hp 5.60 kW
22.3 amps
26.1 amps
33.6 amps
41.2 amps
57.0 amps
72.0 amps
10.00 hp 7.46 kW
26.0 amps
30.0 amps
37.0 amps
45.0 amps
60.0 amps
75.0 amps
49
7
/
8
”