Page 24
Royal Series Water Temperature Control Units
3-10 Making Electrical Connections
Royal Series systems are designed for three-phase voltage 
operation. Refer to the unit nameplate for proper voltage and 
amperage requirements. 
Make sure you provide a correctly sized and protected supply of 
electrical power to the unit. 
Important!
Refer to National Electric Code (NEC) Article 430-24 through 430-26
for proper feeder conductor and supply disconnect sizing.
Maintain a safe ground and disconnect the power supply before 
servicing the unit. A qualified electrician should make electrical 
connections, and disconnect and lock out electricity using OSHA 
29CFR 1910.147 standards when you need a service call. 
Check serial tag voltage and amperage requirements and make sure 
your electrical service conforms before making any electrical 
connections. Total running amps for Royal Series systems are 
listed on the nameplate. Customer connections can be run to the 
supply terminals from either side of the unit. Make sure that all 
three phases are wired correctly. If not wired properly, the unit will 
run backwards. Again, check the unit nameplate for correct 
voltage and amperage. 
 
 
!
DANGER
Improper electrical connections 
can damage the unit and cause 
serious operator injury or death! 