3 corrective maintenance – Sterlco SGBD Series Batch Gravimetric Blenders User Manual
Page 72

BLN1-600
Chapter 5: Maintenance
72 of 110
5-3 Corrective Maintenance
Electrical
This section is designed to give the operator an overview of the electrical system that controls
the Slide Gate/Auger blending system. Since the blender’s control panel is a self-contained
pluggable item, seldom will a maintenance person be required to enter the control panel. For
purposes of understanding the system, it is advisable that the maintenance personnel be
familiar with not only the internal workings of the control panel, but also with the input and
output signals to the Slide Gate/Auger blender.
This section includes the following:
• Internal components of the control panel
• Input signal to the control panel
• Output signals from the control panel
Internal Components of the Control Panel
This section describes the internal components of the Slide Gate/Auger blending system
control panel. It is not the intent of this section to completely familiarize the reader with the
details on industrial control panel construction or standards, but simply to familiarize the
reader with the major components inside the control panel.
The customer must supply 120-240/1/60 or 110-220/1/50 voltage via wires L1 & L2 (N).
Please insure that the earth ground connection is properly connected to an established earth
ground.
• “Power on” is indicated by a lighted on/off selector switch.
• “Slide gate below mixer” switch controls position of optional slide gate.
• “Safety Active” light displays status of safety interlock circuit.
• Audible alarm horn alerts operator to blender fault.
• See Installation Packet supplied with unit for complete electrical schematics.