10 Technical data
10.1 Specifications
General
HF63
HF65
Device type
Humidity temperature transmitter
with analog output signals
Humidity temperature transmitter with
digital output
Circuit type
3-wire
Mechanical configuration types
D and W
Power supply and connections
HF63
HF65
Supply voltage (VDD)
15…40 VDC or 12…28 VAC
85…265 VAC
5…40 VDC or 12…28 VAC
85…265 VAC
Nominal current consumption
(low voltage models)
< 50 mA
Model with USB interface: 50 mA
Model with Ethernet interface: 300 mA
Cable fittings
Terminal block and M16 cable grip or
½” conduit adapter
Connector (USB or Ethernet), terminal
block (power supply and RS-485) and
M16 cable grip or ½” conduit adapter
Polarity protection
(low voltage models)
Protective diode on V+
Humidity measurement
HF63
HF65
Sensor ROTRONIC
Hygromer
®
IN1
Measuring range
0…100 %RH
Measurement accuracy at 23 °C
±1.0 %RH
Repeatability 0.3
%RH
Long term stability
< 1 %RH / year
Sensor time constant
Typical 10 sec, 63% of a 35 to 80 %RH step change (1m/sec air flow at sensor)
Temperature measurement
HF63
HF65
Sensor
Pt100 RTD, IEC 751 1/3 class B
Measuring range limits
-100…150 °C / -148…302 °F
Measurement accuracy at 23 °C
±0.2 °C
Repeatability 0.05°C
Long term stability
< 0.1°C / year
Sensor time constant
Typical 4 sec, 63% of a step change (1m/sec air flow at sensor)
Calculated parameters
HF63
HF65
Psychrometric calculations
Dew or frost point (user configurable option)