8.1 Configuration 1
Daytime the lamps in a group are always off
At dusk the photocells on the lamps detect it is dark, the lamps should come on at
20%
At dawn the photocells on the lamp detect it is light, the lamps should switch off
If a motion detect is detected on camera 1 the lamps should go into deterrent mode
for 60 seconds, SOS fast
Camera 1 raises a hardware event when motion is detected, this event is called
Cam1MotionDetect.
Create the following events:
Group1OnTrigger1
Group1DeterTrigger
Group1OffTrigger
Create an alarm called Group1PhotocellDay, select the triggering event as Vario IP Lamp
and Photocell Day. Click the select button and associate Lamp 1 and Lamp 2 with this
alarm. Click the select button at the bottom of the screen next to Events triggered by alarm
and select the Group1OffTrigger.
Create a second alarm called Group1PhotocellNight, select the triggering event as Vario IP
Lamp and Photocell Night. Click the select button and associate Lamp 1 and Lamp 2 with
this alarm. Click the select button at the bottom of the screen next to Events triggered by
alarm and select the Group1OnTrigger1.
Create a third alarm called Group1CameraMotDet, select the triggering event as System
Events and External Event. Click the select button and associate Camera1MotionDetect
hardware event with this alarm. Change the activation period to Event based and select the
start event as Group1OnTrigger1 and the off event as Group1OffTrigger. Click the select
button at the bottom of the screen next to Events triggered by alarm and select the
Group1DeterTrigger.
Select Group 1 in the Raytec Vario IP node and set the following information on the page.
Group On Trigger 1
Event: Group1OnTrigger1
Power: 20%
Lamp stays on
Group Deter Trigger
Event: Group1DeterTrigger
Deterrent ends after: 60 seconds
And reverts back to previous power level
Mode: SOS
Speed: Fast
Group Off Trigger