beautypg.com

5 using and configuring alarms – Raytec Milestone Plug-in User Manual

Page 18

background image

17


Raytec Global (excluding Americas) - Tel: +44 (0) 1670520055 [email protected]
Raytec Americas - Tel: +1 613 270 9990 Toll Free: +1 888 505 8335 [email protected]

www.rayteccctv.com

Speed
This determines the speed at which the deterrent mode will run at, selectable speeds are
slow, medium or fast.

6.4.3 Group/Lamp Off Trigger

When associated with an event this switches the illuminators off.


6.4.4 Group/Lamp Boost Trigger

When associated with an event this puts the illuminators into boost mode. Boost mode is a
special mode where the power is increased to 120% for 10 seconds. Note that once boost
mode has been activated on an illuminator there is a 2 minute cool down period before it
can be activated again.

6.5 Using and Configuring Alarms



6.5.1 Using alarms to trigger events and thus illuminators

Pre-configured alarms in the Milestone system, e.g. on motion detection from 3

rd

party

devices like a PIR, can be set to trigger system events, which in turn can
activate/deactivate your VARIO IP illuminators.


Open the XProtect Smart Management application
On the left hand side select the Alarms section, and select the specific alarm that you want
to use e.g. PIR motion detect. This is just an example of a pre-configured alarm that you
may have already named and set within your Milestone system.

In the alarm window, you can relate your chosen alarm to a specific illuminator related
event in

‘Other’ section, by using the ‘Events triggered by alarm’ drop down list. This in turn

can activate/deactivate your VARIO IP illuminator/group of illuminators in accordance with
specific illuminator settings.