Error messages, 5 parameter – NORD Drivesystems BU2100 User Manual
Page 29
5 Parameter
BU 2100 GB-2213
29
Para-
meter
Parameter name
Recommended setting
Remarks
SK 5xxE
SK
180E … SK 2xxE
P545
Actual BUS value 3
According to the
function:
Not available
Only SK
500E … 535E
P546
Function Setpoint BUS
value
According to the
function:
According
to
the
function:
SK 54xE and SK
180E …
SK 2xxE: up to 5 setpoints
each
P547
Function BUS setpoint
2
According to the
function:
Not available
Only SK
500E … 535E
P548
Function BUS setpoint
3
According to the
function:
Not available
Only SK
500E … 535E
Info parameters
P700
Present
Operating
status
Fault / Warnings / Reason for
starting disabled condition
P701
Last fault
P740
Process data BUS In
P741
Process data BUS Out
P742
Data base version
P744
Configuration
Not relevant
P745
Module version
Not available
P746
Module status
Not available
Possible values
Bit
Meaning
0
Module initialised
1
Cyclical communication
2
Vacant
3
Vacant
4
Error 1
5
Error 2
6
Error 3
7
Vacant
8-15
Module number
EtherNet/IP = 23
Table of Errors
Error
Meaning
3
2
1
0
0
0
No error
0
0
1
No communication
with ASIC
0
1
0
Bus Timeout
0
1
1
P513 timeout
1
0
0
IP already assigned
1
0
1
General config. error
1
1
0
No Ethernet cable
1
1
1
Communication error
P748
CANopen status
Not relevant for
SK TU3 modules
System bus status
Error messages
Error messages from the module - present errors or archived messages relating to the last error - can
be read out via the module parameter (P170). The error messages are lost if the module is switched
off.