1 assembly, Assembly, Table 6: example: "switch fi on and off + setpoint – NORD Drivesystems BU2100 User Manual
Page 17: Table 7: assembly instance, 4 communication and protocol
4 Communication and Protocol
BU 2100 GB-2213
17
Parameter
Setting value
Meaning
Parameter number
SK
180E …
SK 2xxE,
SK 54xE
SK
500E …
SK 535E
Maximum frequency
50.0
50 Hz
P105
P105
Actual bus value 1
1
Actual frequency
P543[-01]
P543
Function Bus setpoint 1
1
Setpoint frequency
P546[-01]
P546
Order to FI
Response from FI
Control word
Setpoint 1
Status word
Actual value
1
Explanation
- - -
- - -
0000h
0000h
- - -
- - -
xx40h
0000h
Switch-on of the mains voltage to the FI
047Eh
0000h
xx31h
0000h
Sets the FI in the status "Standby"
047Fh
2000h
xx37h
2000h
Sets the FI to the status "Operation
enabled" with the setpoint 50%.
The FI is enabled, the motor is supplied with current and rotates with a frequency of 25 Hz.
0047Eh
2000h
xx31h
0000h
Sets the FI to "Standby" status. The
motor runs on its parameterised ramp up
to speed 0 and then the power is
switched off.
The FI is locked again and the motor is without current.
047Fh
1000h
xx37h
1000h
Sets the FI to the status "Operation
enabled" with the setpoint 25 %.
The FI is enabled, the motor is supplied with current and rotates with a frequency of 12.5 Hz.
Table 6: Example: "Switch FI on and off + setpoint"
4.2 Transfer of Data in the Bus System (I/O connections)
Process data is exchanged between the SK xUx-EIP bus module and the EtherNet/IP Master via I/O
connections. An "Exclusive Owner" connection can be opened, through which the setpoints and actual
values can be exchanged. In addition, two "Listen Only" connections can be opened, through which
the actual values of the FI can be read.
4.2.1 Assembly
Only process data, but no protocol information can be transmitted via the I/O Message Object.
Assignment of the relevant setpoints and actual values is performed via the Assembly Object. The
following table lists several pre-defined configurations (Instances).
Instance
Length
(Byte)
Meaning*
Device class
(SK ...)
Data length
100
12
STW + SW1 + SW2 + SW3 + SW4 + SW5
TU3-EIP,
TU4-EIP
Fixed
101
12
ZSW + IW1 + IW2 + IW3 + IW4 + IW5
TU3-EIP,
TU4-EIP
Fixed
110
50
Bus module outputs + four FIs
Structure for each FI:
STW + SW1 + SW2 + SW3 + SW4 + SW5
TU4-EIP
Variable
111
50
Module inputs + four FIs
Structure for each FI:
ZSW + IW1 + IW2 + IW3 + IW4 + IW5
TU4-EIP
Variable
* STW = Control word, ZSW = Status word, SW = Setpoint, IW = Actual value
Table 7: Assembly Instance