beautypg.com

Dwyer ULTM User Manual

Page 12

background image

All notes are explained in section 5.4.

Page 11

LPST (

14

)

Low power timer 1-99999, 0.150 – 8.000,

1-99999, 0.150 – 8.000, 0-1, 0-1

Long standby interval in minutes
Distance to low level in meters
Short standby interval in minutes
Distance to high level in meters
Disable (0) or enable (1)
0 - No SMS are sent when in the “Long Standby Mode”. 1 – SMS are sent
when in “Long Standby Mode”.

Communication and Alert Items (Metric)

Item

APP (

1

)

EMP (

2

)

FUL (

2

)

VAL (

3

)

UNT (

3

)

UNT (

3

)

FBD (

2

)

NBD (

2

)

RAT (

4

)

TMP (

5

)

SNS (

5

)

RSD (

6

)

RSC (

6

)

RST (

6

)

GMAN
ENDT (

8

)

DSDT (

8

)

CUB (

7

)

CYLV (

7

)

CYLV (

7

)

CYLH (

7

)

CYLH (

7

)

TEL1 (9)
TEL1 (

9

)

SMST (

10

)

AFE (

11

)

ATF (

12

)

ATF (

12

)

ARF (

13

)

ARF (

13

)

Description

Application type

Empty level
Full level
Value to display

Units for VAL=1,2,4,5

Units for VAL=3,6

Far blocking distance
Near blocking distance
Filling (tracking) rate

Temperature unit system

Temperature sensor

Reset to factory defaults
Reset hour counter
Restart ULTM
Get manufacturer data
Enable USB monitoring
Disable USB monitoring

Cubic tank
Vertical cylindrical tank

Vertical cylindrical tank
with concave bottom

Horizontal cylindrical tank
with curved sides
Horizontal cylindrical tank
with flat sides

Cell-phone destination
SMS periodic interval

Full / Empty alerts

Theft alert for VAL=1,2,4,5

Theft alerts for VAL=3,6

Refill alerts for
VAL=1,2,4,5

Refill alerts for VAL=3,6

Possible values

0
1
0.50 – 26.00
0.50 – 26.00
1
2
3
4
5
6
1
2
3
4

0.50 – 26.00
0.50 – 26.00
0
1
2
3
3
4
0
1
2

None
None
None
None
None
None

0.00-300.00, 0.00-300.00
0.00-300.00, 0.00-300.00, 0

0.00-300.00, 0.00-300.00,
0.01-300.00

0.000-99.99, 0.000-99.99,
0.001-99.99
0.000-99.99, 0.000-99.99, 0

XXXXXXXXXXXXXX
XXXXXXXXXXXXXX
0
180-3999999
0
1
0, 0
0.16-4.00, 0
0, 0
0.16-4.00, 0
0, 1.4-26.00
0, 0, 1
0.16-4.00, 0, 1-3
0, 0, 1
0.16-4.00, 0, 1-3
0, 0.8-26, 1-3

Basic Setup (English)

Advanced Setup (English)

Resetting and ID Options (English)

Tank Shapes and Dimensions (English)

5.3 List for English Unit System

Communication and Alert Items (English)

Value description

High power
Low power
Distance in feet
Distance in feet
Level
Distance
Volume (set also tank shape)
% Level
% Distance
% Volume (set also tank shape)
Meter (see list for metric units)
Feet
Liter (see list for metric units)
Gallons (US)

Distance in feet
Distance in feet
3 feet / minute
6 feet / minute
15 feet / minute
30 feet / minute
Celsius
Fahrenheit
Internal sensor
External sensor
Average of both

Response is serial number and manufacturer date: dd-mm-yyyy

-
Width and depth (horizontal dimensions) in feet
Height of tank = EMP value in feet
Diameter of tank in feet
Height of tank = EMP value in feet
Diameter of tank in feet
Breadth of bottom in feet
Length, diameter and curved breadth in feet

Length and diameter in feet

Exactly 14 digits where X is any digit 0-9 or *,+,-
No periodic reports
Interval in seconds
No alerts
Alerts activate
No alerts
Normal consumption in inch/minute
No alerts
Normal consumption in inch/minute
Normal consumption in gallon/minute
No alerts
Minimal alerted level change in inch and minimum fill duration in minutes
No alerts
Minimal alerted level change in inch and minimum fill duration in minutes
Minimal alerted level change in gallons and minimum fill duration in minutes