5.1.2 Range of Whole Number Values
A range of whole number values is presented with a hyphen. For example: 1 - 99.
This entry means that the value may be any whole number between 1 and 99.

5.1.3 Several Distinct Values
When a parameter can be one of a few distinct values, each value is listed on
separate lines with an explanation. For example:

5.1.4 Two Parameters for the Same Command
An entry such as 1-9999, 0.150-8.000 means that the command is made of two
parameters and requires two values. A comma separates the two values. In this
example the first value may be any whole number between 1 and 9999. The
second value may be any number between 0.150 and 8.000.

5.1.5 Two Parameters with One Parameter Fixed
An entry such as 1-99, 0 means that the configuration item requires two values, but
the second value must be 0. The first value in this example may be any whole
number between 1 and 99.

The user may select one of two units systems: Metric or English. A separate
command list is provided below for each unit system. The user can select their
preferred unit system with the UNT command.

Command
VAL (3)

Command Description
Value to display

Possible Values
1
2
3

Value Description
Level
Distance
Volume (set also tank
shape)

Page 10

Item

APP (

1

)

EMP (

2

)

FUL (

2

)

VAL (

3

)

UNT (

3

)

UNT (

3

)

FBD (

2

)

NBD (

2

)

RAT (

4

)

TMP (

5

)

SNS (

5

)

RSD (

6

)

RSC (

6

)

RST (

6

)

GMAN
ENDT (

8

)

DSDT (

8

)

CUB (

7

)

CYLV (

7

)

CYLV (

7

)

CYLH (

7

)

CYLH (

7

)

TEL1 (9)
TEL1 (

9

)

SMST (

10

)

AFE (

11

)

ATF (

12

)

ATF (

12

)

ARF (

13

)

ARF (

13

)

Description

Application type

Empty level
Full level
Value to display

Units for VAL=1,2,4,5

Units for VAL=3,6

Far blocking distance
Near blocking distance
Filling (tracking) rate

Temperature unit system

Temperature sensor

Reset to factory defaults
Reset hour counter
Restart ULTM
Get manufacturer data
Enable USB monitoring
Disable USB monitoring

Cubic tank
Vertical cylindrical tank

Vertical cylindrical tank
with concave bottom

Horizontal cylindrical tank
with curved sides
Horizontal cylindrical tank
with flat sides

Cell-phone destination
SMS periodic interval

Full / Empty alerts

Theft alert for VAL=1,2,4,5

Theft alerts for VAL=3,6

Refill alerts for
VAL=1,2,4,5

Refill alerts for VAL=3,6

Possible values

0
1
0.150 – 8.000
0.150 – 8.000
1
2
3
4
5
6
1
2
3
4

0.150 – 8.000
0.150 – 8.000
0
1
2
3
3
4
0
1
2

None
None
None
None
None
None

0.00-99.99, 0.00-99.99
0.00-99.99, 0.00-99.99, 0

0.00-99.99, 0.00-99.99,
0.00-99.99

0.000-99.99, 0.000-99.99,
0.001-99.99
0.000-99.99, 0.000-99.99, 0

XXXXXXXXXXXXXX
XXXXXXXXXXXXXX
0
180-3999999
0
1
0, 0
4-99, 0
0, 0
4-99, 0
0, 5-500
0, 0, 1
4-99, 0, 1-3
0, 0, 1
4-99, 0, 1-3
0, 3-500, 1-3

Basic Setup (Metric)

Advanced Setup (Metric)

Resetting and ID Options (Metric)

Tank Shapes and Dimensions (Metric)

5.2 List for Metric Unit System

Communication and Alert Items (Metric)

Value description

High power
Low power
Distance in meters
Distance in meters
Level
Distance
Volume (set also tank shape)
% Level
% Distance
% Volume (set also tank shape)
Meter
Feet (see list for English units)
Liter
US Gallons (see list for English units)

Distance in meters
Distance in meters
1 meter / minute
2 meter / minute
5 meter / minute
10 meter / minute
Celsius
Fahrenheit
Internal sensor
External sensor
Average of both

Response is serial number and manufacturer date: dd-mm-yyyy

-
Width and depth (horizontal dimensions) in meter
Height of tank = EMP value in meter
Diameter of tank in meter
Height of tank = EMP value in meter
Diameter of tank in meter
Breadth of bottom in meter
Length, diameter and curved breadth in meter.

Length and diameter in meter

Exactly 14 digits where X is any digit 0-9 or *,+,-
No periodic reports
Interval in seconds
No alerts
Alerts activate
No alerts
Normal consumption in mm/minute
No alerts
Normal consumption in mm/minute
Normal consumption in liter/minute
No alerts
Minimal alerted level change in mm and minimum fill duration in minutes
No alerts
Minimal alerted level change in mm and minimum fill duration in minutes
Minimal alerted level change in liters and minimum fill duration in minutes