beautypg.com

Appendix i – ufm specification, F - ufm, 10 appendix i – ufm specification – Dwyer UFM User Manual

Page 25

background image

F - UFM

Issue 1.4

Page 25

10

Appendix I – UFM Specification

Table 1 lists the UFM Product Specification.

General

Measuring Technique

Transit time

Measurement channels

1

Timing Resolution

±50 ps

Turn down ratio

200:1

Flow velocity range

0.1 to 10 m/s

Applicable Fluid types

Clean water with < 3% by volume of particulate content.

Accuracy

±3% of flow reading for flow rate >0.3 m/s

Repeatability

±0.5% of measured value

Selectable units

Velocity: m/s, ft/s
Flow Rate:l/s, l/min, gal/s, gal/min, USgal/s, USgal/min,
m

3

/min, m

3

/hr

Volume: liters, m3, gals, USgals

Languages supported

English only

Power input

12 – 24 V ac or dc

Power consumption

7 VA maximum

Cable

5 m screened 6 core

Pulse Output

Output

Opto-isolated MOSFET volt free normally open contact.

Isolation

2500V

Pulse width

Default value 25 ms; programmable range 3 – 99 ms

Pulse repetition rate

Up to 166 pulses/sec (depending on pulse width)

Frequency mode

200 Hz maximum

Maximum load voltage/current

48V AC / 500mA

Current Output

Output

4 – 20 mA

Resolution

0.1% of full scale

Maximum load

620 Ω

Isolation

1500 V opto-isolated

Alarm current

3.5 mA

Enclosure

Material

Plastic Polycarbonate

Fixing

Pipe mountable

Degree of Protection

IP54

Flammability Rating

UL94 V-0

Dimensions

10 inches x 2 inches x 3.6 inches (electronics + guide rail)

Weight

1.1 lb

Environmental

Pipe temperature

32°F to 185°F (0°C to 85°C)

Operating temperature (Electronics)

32°F to 122°F (0°C to 50°C )