4.8 Current Output
The isolated 4-20 mA is a current source and can drive into a maximum load of 620
Ω.
The 4-20 mA current output is available at the Red and Black wires. The polarities are shown
in Figure 8.
The alarm current due to a flow outside the range specified or due to a loss of signal is set at
3.5 mA.
4.9 Cable Screen
For full immunity to electrical interference the screen of the cable should be connected to
Earth.