beautypg.com

Ufm interface cable, Connecting the ufm to the supply, Pulse output connection – Dwyer UFM User Manual

Page 12: F - ufm, 5 ufm interface cable, 6 connecting the ufm to the supply, 7 pulse output connection

background image

F - UFM

Issue 1.4

Page 12

4.5 UFM interface cable

The UFM interface cable supplied is a 6-core cable and is shown in Figure 8.












The polarity of the wires is as follows:









The un-insulated wire is the connection to the screen of the cable and should be earthed for full
immunity to electrical noise.

4.6 Connecting the UFM to the Supply

The UFM will operate within the voltage range 12

– 24 V ac/dc. Connect the external power

supply to the Brown and Blue wires of the six core cable. For full compliance with EMC
regulation a 12 V supply is recommended for domestic and light industrial applications.

4.7 Pulse Output connection

The isolated pulse output is provided by a SPNO MOSFET relay which has a maximum load
current of 500 mA and maximum load voltage of 48 V ac. The relay also provides 2500 V
isolation.
The pulse output is available at the White and Green wires. Electrically this is a volt free
contact closure.

Power

Pulse

4-20 mA

Figure 8 UFM Interface Cable

12/24 V Input (+)

12/24 V Return (-)

Pulse Output

Pulse Return

4-20 mA Output (+) (Polar Sensitive)

4-20 mA Return (-) (Polar Sensitive)

Un-insulated screen