Relocation of guide rail

If it is necessary to relocated the guide rail and sensor assembly use the following procedure

1. Remove complete assembly from the pipe
2. Insert a small screwdriver in the hole at the end of the guide rail moulding and lever

up the clip holding the electronics assembly by pressing down on the screwdriver as
shown in figure 18.

3. Repeat 2 on the other end and then pull off the electronics unit.

Figure 18


4. Disconnect the sensors
5. Remove the original grease from the sensors
6. Push the sensor blocks into the guide rail so that the washers and locking screws

can be refitted.

7. Place a bead of grease down the center of the sensor block using the syringe

provided. See illustration on fitting the guide rail to the pipe for recommended bead
size.

8. Follow the original procedure for installing the guide rail on the pipe.