Warning, Flex-pro 5.1 wiring terminals and i/o schematics, Page 9 – Blue-White FLEX-PRO A2 ProSeries Peristaltic Pump User Manual
Page 9: T2 t4 t1, Power, Output input p1
Risk of electric shock – cord connected models are supplied with a grounding
conductor and grounding-type attachment plug. To reduce risk of electric shock, be
certain that it is connected only to a properly grounded, grounding-type receptacle.
Electrical connections and grounding (earthing) must conform to local wiring codes. Be
certain that a grounding conductor is connected to terminal T11-1 located in wiring
compartment.
Risk of electric shock - Disconnect electricity before removing wiring compartment
cover.
WARNING
T1
1
3
PLS
4
4-20
(+)
2
Motor Active
(-)
5
+
-
ACTIVE 4-20mA
TRANSMITTER
SOURCE
GND (-)
4-20(+)
INPUT:
4-20 mA
INPUT:
FREQUENCY, AC
SINE WAVE, TTL,
CMOS
FUNCTION
TERM
PIN #
RATING
ELECTRICAL SP.
BLOCK DIAGRAM
T1
T1
T1
T1
T4
T4
T4
1
3
3
4
3
4
5
(+) POSITIVE
SIGNAL
(-) NEGATIVE
OUTPUT:
4-20 mA
OUTPUT:
RELAY, 3 AMP
OUTPUT:
OPEN COLLECTOR
MOTOR ACTIVE
T6
T6
2
1
(+) POSITIVE
(-) NEGATIVE
T7
1
T7
T7
2
3
120 OHM
IMPEDANCE, NON
POWERED LOOP
6 TO 30 VOLT DC
1 AMP MAX.
120 OHM
RESISTANCE
ACTIVE LOOP
Form C
3 AMP MAX AT
250 VAC,
3 AMP MAX AT
30 VOLT DC
0-1000 HZ MAX.
NO VOLTAGE
(+)
(-)
NO
C
NC
SWITCH LOAD
3 AMP MAX @ 250V AC
3 AMP MAX @ 30V DC
EXTERNAL DEVICE
6 TO 30V DC
OPEN CIRCUIT
IMPEDANCE MUST
BE GREATER THAN
50K OHM
4-20mA RECEIVER
600 OHM LOAD MAX.
(+)
(-)
Risk of electric shock - All
wiring must be insulated
and rated 300V minimum.
Terminals T1 Thru T8
Plug type
16 - 24 AWG
Power Input Terminal T11
Plug type
14 - 30 AWG
Single or dual pump (series) input.
Loop voltage must not exceed 24 Volts.
Page 9
Flex-Pro
5.1
Wiring Terminals and I/O Schematics
115V
FUSE 5A SLOW
BLOW (20 X 5MM)
POWER
T11
GROUND
N EUTRAL
(COMMON)
LINE
(HOT)
1
2
3
S1
OUTPUT
INPUT
P1
TO COM
BOARD
T7
RELAY
OUT
T3
REMOTE
IN
T2
T4
T1
FVS
3
1
2
DRY
RMT
COM
4-20mA
1 2 3
N.C. COM N.O.
1 2
(-)
(+)
1
3
PLS
4
4-20
(+)
1
2
(-)
(+)
3
4
5
(+)
(-)
SIG
DIR
T6
RS-232
T12
POWER
F1
2
Motor Active
(-)
5
T1
1
3
PLS
4
4-20
(+)
2
Motor Active
(-)
5
+
-
FREQUENCY
TRANSMITTER
SOURCE
GND (-)
PULSE
T4
FVS
3
4
5
(+)
(-)
SIG
BLUE-WHITE
FVS SENSOR
GND (-)
SIGNAL
PWR (+)
RED (+)
BLACK (-)
BARE
T3
REMOTE
IN
3
1
2
DRY
RMT
COM
T3
T3
1
2
(+) POSITIVE
(-) NEGATIVE
T3
T3
2
3
(+) POSITIVE
(-) NEGATIVE
T3
REMOTE
IN
3
1
2
DRY
RMT
COM
T4
T4
4
5
SIGNAL
(-) NEGATIVE
T4
FVS
3
4
5
(+)
(-)
SIG
BLUE-WHITE
MICRO-FLO
FLOWMETER
PULSE OUTPUT
GND (-)
SIGNAL
PWR (+)
NEGATIVE (-)
SIGNAL
1 2
(-)
(+)
T6
T7
RELAY
OUT
1 2 3
N.C. COM N.O.
(-)
(+)
T1
1
3
PLS
4
4-20
(+)
2
Motor Active
(-)
5
GND (-)
T1
T1
2
3
CLOSED WHILE MOTOR
IS ENERGIZED
NEGATIVE (-)
SIGNAL OUT
4.7K OHM
MOTOR
ACTIVE
5 TO 24 VDC
INPUT:
POWER
T11
1
T11
T11
2
3
T11
GROUND
N EUTRAL
(COMMON)
LINE
(HOT)
1
2
3
POWER
AC
VOLTAGE
115V OR 230V AC
MANUAL SWITCH
50 / 60 HZ
100W
GROUND
NEUTRAL
LINE (HOT)
115V
POWER
S1
POWER
VOLTAGE
SWITCH
SWITCH
FROM
115V TO 230V
FUSE
F1
N/A
5 AMP
5A SLOW BLOW
(20 X 5MM)
(+) POSITIVE
(-) NEGATIVE
(-) NEGATIVE
(+) POSITIVE
INPUT:
FVS SYSTEM
(FLOW VERIFICATION
SENSOR)
FS or FP MICRO-FLO
FLOW METER ONLY
INPUT:
FVS SYSTEM
(FLOW VERIFICATION
SENSOR)
FV SENSOR ONLY
INPUT:
REMOTE
START / STOP
(DRY CONTACT C.)
INPUT:
REMOTE
START / STOP
(WET CONTACT C.)
NORM. CLOSED
NORM. OPEN
COMMON
4-20
COMMON
SIGNAL