Datalogger, Datalogger 16, Datalogger store delete – Badger Meter MC4000 Diagnostic Test Equipment User Manual
Page 16: Datalogger store on, Datalogger store off

oPerATIon
P1
bar
74.32
T
°C
86.5
Q
l/min
38.4
P2
bar
76.12
Datalogger
Recording Measurements
The internal memory can save all displayed measurements The USB data port permits the uploading of the stored data to a
PC where for further processing The internal memory permits 224 individual records with a total capacity of 2 5 MB Use the
MC4000 keyboard to initializes each individual record After initializing the record location, pressing ESC switches the display
into measuring mode In measuring mode, an M icon indicates an active datalogging session
P1
bar
74.32
T
°C
86.5
Q
l/min
38.4
P2
bar
76.12
M
Logging Active
Indication
Datalogging Memory Commands
The first menu screen allows a choice to start, stop or delete the datalogger memory
DATALOGGER
STORE DELETE
This command erases datalogger memory
All records are deleted
DATALOGGER
STORE ON
This command starts the recording of data at the selected
interval rate Each record automatically adds the date and time
from an internal real time clock
DATALOGGER
STORE OFF
Stops recording the datalogging information to memory
Page 16