ORION® Water Endpoints
INTEGRAL ENDPOINT INSTALLATION
ORION Fixed Network, Migratable and Classic endpoints
are available in an integral configuration, in which the
endpoint and encoder are connected in one assembly .
Mounting an Integral Endpoint on the Meter
An integral endpoint can be installed on any Badger Meter
disc, turbo or compound meter by mounting the assembly
onto the bayonet of the meter and rotating it into its
locking position . See
Figure 26: Integral assembly on meter
1 . Loosen the security screw on the endpoint
encoder assembly prior to mounting the assembly
on the meter .
2 . Mount the assembly housing on the
meter bayonet .
3 . Turn the assembly clockwise 1/4 turn to lock the
assembly into place on the meter .
4 . After the assembly is mounted on the meter,
tighten the security screw to secure the assembly
to the register .
Figure 26: Integral assembly on meter
Integral Endpoint with Three Feet of Wire
An integral endpoint can be ordered with three feet of wire
inside the assembly housing . Units with additional wire are
marked “3 Ft Wire” on the side of the integral bracket on
a serial number label . With this option, the endpoint can
be removed from the housing and mounted remote from
the encoder . See
"Removing an Integral Endpoint from the
Figure 27: Additional wire noted on label
Security Screw
Meter Bayonet
3 Ft Wire
noted on
label