KROHNE OPTISONIC 7060 EN User Manual
Page 9
OPTISONIC 7060
Electrical & mechanical installation manual 730962.31.00 page 9 of 52
2.2 Conformity,
Configuration,
Technical
Data
2.2.1 CE
Certificate
The OPTISONIC 7060 has been developed, manufactured and tested in accordance with the
following
EC
directives:
• Pressure Equipment Directive 97/23/EC
• Directive 94/9/EC (ATEX100)
• EMC Directive 89/336/EC
Conformity with above directives has been verified and the equipment given the CE label.
2.2.2 Technical
Data
Flow
rate
range
Max gas
velocity
Max flowrate
Max flowrate @
30m/s
Minimum flowrate
Meter size
[m/s] [ft/s] [m3/h]
[ft3/h] [m3/h] [ft3/h] [m3/h] [ft3/h]
DN 50
2"
57 187
402
14197
212
7486,74 7,1 249
DN 65
2,5"
57 187
680
24014
357
12607,4 11,9 417
DN 80
3"
57
187
1000
35315
540
19070
18
630
DN 100
4"
53
174
1600
56503
900
31783
30
1050
DN 150
6"
45
148
3000
105944
2000
70629
67
2345
DN 200
8"
43
141
4800
169510
3360
118657
112
3920
DN 250
10"
45
148
7800
275454
5220
184342
174
6090
DN 300
12"
32
105
7800
275454
7380
260622
246
8610
DN 400
16"
30
98 12000
423776 12000
423776
400 14000
DN 450
18"
30
98 17170
606353 17170
606353
572 20020
DN 500
20"
30
98 21200
748761 21200
748761
707 24745
DN 600
24"
30
98 30550
1078993 30550 1078993
1018 35630
• Any flow rates given above are also valid in the bidirectional mode.