beautypg.com

KROHNE OPTISONIC 7060 EN User Manual

Page 9

background image

OPTISONIC 7060

Electrical & mechanical installation manual 730962.31.00 page 9 of 52

2.2 Conformity,

Configuration,

Technical

Data

2.2.1 CE

Certificate

The OPTISONIC 7060 has been developed, manufactured and tested in accordance with the

following

EC

directives:

• Pressure Equipment Directive 97/23/EC

• Directive 94/9/EC (ATEX100)

• EMC Directive 89/336/EC

Conformity with above directives has been verified and the equipment given the CE label.

2.2.2 Technical

Data

Flow

rate

range

Max gas

velocity

Max flowrate

Max flowrate @

30m/s

Minimum flowrate

Meter size

[m/s] [ft/s] [m3/h]

[ft3/h] [m3/h] [ft3/h] [m3/h] [ft3/h]

DN 50

2"

57 187

402

14197

212

7486,74 7,1 249

DN 65

2,5"

57 187

680

24014

357

12607,4 11,9 417

DN 80

3"

57

187

1000

35315

540

19070

18

630

DN 100

4"

53

174

1600

56503

900

31783

30

1050

DN 150

6"

45

148

3000

105944

2000

70629

67

2345

DN 200

8"

43

141

4800

169510

3360

118657

112

3920

DN 250

10"

45

148

7800

275454

5220

184342

174

6090

DN 300

12"

32

105

7800

275454

7380

260622

246

8610

DN 400

16"

30

98 12000

423776 12000

423776

400 14000

DN 450

18"

30

98 17170

606353 17170

606353

572 20020

DN 500

20"

30

98 21200

748761 21200

748761

707 24745

DN 600

24"

30

98 30550

1078993 30550 1078993

1018 35630

• Any flow rates given above are also valid in the bidirectional mode.