Electrical & mechanical installation manual 730962.31.00 page 33 of 52
Safety-relevant data of inputs and outputs
Output circuit
Intrinsically safe EEX ia IIA / IIB / IIC
Non-intrinsically
safe U
M
= 253 V
U
o
= 22.1 V
EEx ia IIA
EEx ia IIC
I
o
[mA]
P
o
[mW]
C
o
[nF]
L
o
[mH]
C
o
[nF]
L
o
[mH]
155 / 155
857 / 857
4100
7
163
1
Active current output
Terminals 31/32
Characteristic curve: linear
Internal capacity C
I
= 4 nF, internal inductance L
I
= 0.075 mH
Only for connection to passive, intrinsically safe circuits or intrinsically safe
circuits with the following maximum values: U
I
= 30 V
U
B
= 18 V
I
B
= 35 mA
Passive current
output
Terminals 31/32
U
I
= 30 V
I
I
= 100 mA
P
I
= 750 mW
C
I
= 4 nF
L
I
= 0.075 mH
U
B
= 30 V
I
B
= 35 mA
Digital output
Terminals 51/52,
41/42, 81/82
U
I
= 30 V
I
I
= 100 mA
P
I
= 750 mW
C
I
= 4 nF
L
I
= 0.075 mH
U
B
= 30 V
I
B
= 100 mA
RS 485
Terminals 81/82
Characteristic curve: linear
U
o
= 5.88 V
I
o
= 313 mA
P
o
= 460 mW
C
o
= 1000 µF/43 µF
L
o
= 1.5/0.2 mH
U
I
= 10 V
I
I
= 275 mA
P
I
= 1420 mW
U
B
= 5 V
I
B
= 175 mA
PROFIBUS PA
Terminals 33/34
U
I
= 30 V
I
I
= 100 mA
P
I
= 750 mW
EEx ia IIA
EEx ia IIB
EEx ia IIC
Ultrasonic
transducer
connections
Characteristic curve: linear
Max. transmission voltage U
o
= 60.8 V
Short-circuit current I
o
= 95 mA
P
o
= 1444 mW
C
o
= 300 nF
U
o
= 51.2 V
I
o
= 80 mA
P
o
= 1024 mW
C
o
= 187 nF
U
o
= 38.9 V
I
o
= 60 mA
P
o
= 584 mW
C
o
= 34 nF
Special
conditions
For connection to a NAMUR amplifier, the digital output (terminals, 51/52, 41/42,
81/82) can be wired internally as a NAMUR contact by setting a jumper (for details see
Service manual). Open Collector or NAMUR configuration is carried out at the factory in
accordance with the order details. If no configuration was specified in the purchase order,
the digital output is configured as Open Collector.
Digital output as Open Collector
Digital output in accordance with NAMUR
Fig. 3.10: Wiring digital outputs