OPTISONIC 7060

Electrical & mechanical installation manual 730962.31.00 page 10 of 52

Other information

Meter characteristics

Number of measuring paths

< DN80 (4”): 1; >= DN80: 2

Min. Gas velocity

1 m/s (for standard accuracy)

V

min

/v

max

Min.: 1:30

Measuring medium

Gas process

gas,

air

Pressure range

From ambient pressure to 103 bar; higher pressure on request

Temprature range

Standard: -25 °C to + 100 °C
Extended: -25 °C to +180 °C

Measuring accuracy

Reproducibility

< 0.2 of the measured value

Typical measuring uncertainty * < ± 1% of measured value for a flowspeed > 1 m/s (3 ft/s) (2 acoustic path's)

< ± 2% of measured value for a flowspeed > 1 m/s (3 ft/s) (1 acoustic path)

Outputs

Measuring quantities

Act. volume flowrate, act. volume, gas velocity, velocity of sound

Pulse and status outputs

Passive; electrically isolated; open collector; U

Imax

= 30 V, I

Imax

= 100 mA, f

max

= 6

kHz, pulse width = 0.05…1 s or in accordance with NAMUR (EN50227)

Measuring rate

20 measurements /s

Interfaces

MODBUS (RS 485)

ASCII protocol, for parameterisation, measured value inquiry and diagnosis
(9600,8, N.1)

Explosion protection

Europe

II 2G EEx de ib [ia] IIA or IIC T4 in accordance with RL94/9/EG (ATEX) **
Ultrasonic signal converter intrinsically safe “ia”

Power supply

Operating voltage
Voltage limits
When supplied through solar-
panel-fed battery

U

min

= 12 V DC, U

max

= 28.8 V DC

Start-up voltage: 11.8V
Turn-off voltage for integrated total discharge protection: 10.8V

Typical power consumption

<1 W (approx. 37 mA at 24 V DC, approx. 66 mA at 12 V DC)

Ambient conditions

Temperature range

ATEX: - 20 °C to + 60 °C (- 40 °C to + 60 °C on request)
CSA: - 40 °C to + 60 °C

Storage temperature

- 40 °C… + 60 °C

Type of protection

IP 67

Relative humidity

< 95 %

* Related to the measured value in the range 0.1…1 Q

max

with min. straight inlet length of 10

DN and min. straight outlet length of 5 D, for calibrated measuring system


Important


When used in hazardous areas, comply with the required type of explosion protection during

installation (intrinsically safe or increased safety)!

IMPORTANT