beautypg.com

Specifications – GW Instek LCR-914 User Manual

Page 23

background image

LCR-914/915/916 User Manual

21

Specifications


General Specifications
Maximum voltage applied to any terminal:

30V

DC

or 30V

AC

rms

Display: 2000/20000 counts
Overrange Indication:
OL
Battery Life:
80 hours
Low Battery Indicator:
"

" is displayed when the battery

voltage drops below the operating voltage.
Low battery voltage: Approx. 4.5V
Auto Power Off: 10 minutes.
Operating Temperature: No-condensation ≦10°C,
11°C ~ 30°C (≦80% RH),
30°C ~ 40°C (≦75% RH),
40°C ~ 50°C (≦45%RH)
Storage Temperature:
-20°C to 60°C, 0 to 80% R.H. (batteries not fitted)
Temperature Coefficient:
0.15 x (Spec.Accy) / °C, < 18°C or > 28°C.
Measurement: Samples 1.25 times per second normal.
Altitude: 6561.7 ft (2000m).
Weight:
(630g) including battery.
Dimensions (W x H x D):
95mm x 207mm x 52mm with holster.
Accessories:

Accessory

LCR-916

LCR-915

LCR-914

1. Shorting Cube

Standard

Standard

Standard

2. 2Wire Alligator

Clip Set

Standard

Standard

Standard

3. Magnetic Hang

Kit

Standard

Standard

Optional

4.

Battery

Standard

Standard

Standard

5. User Manual

Standard

Standard

Standard

6.

SMD Test Probe Standard

Optional

Optional

7. AC Adapter

Standard

Optional

Optional

8. USB Cable

Standard

Optional

Optional

9. PC Software CD

Standard

Optional

N/A

10. 4Wire DIP Clip

Set

Optional

Optional

Optional

Power Requirements: 1.5V x 4 IEC LR6 or AA size.
External Power Requirements: DC 5V (USB cable or AC
adapter)
Pollution Degree:
2
Safety: Complies with EN 61010-1, IEC 61010-1
EMC:
EN 61326-1

This manual is related to the following products: