beautypg.com

GW Instek PSP Series User Manual

Page 16

background image

PSP SERIES

USER MANUAL

26

*A

Function:

The present output current, the unit is A.

Syntax:

A HEX = 41 0D

Explain:

When the message of Ais sent to the power supply from computer,
the power supply will return the following message immediately:

Aa.aaa 6 characters totally + CR/LF

The contents consist of the uppercase A, the numeral from 0 to 9 and
decimal. Further details is described as follows:

a.aaa = The present output current, the unit: A

*W

Function:

The present output load, the unit is W.

Syntax:

W

HEX = 57 0D

Explain:

When the message of Wis sent to the power supply from
computer, the power supply will return the following message
immediately:

Wwww.w

6 characters totally + CR/LF

The contents consist of the uppercase W, the numeral from 0 to 9 and
decimal. Further details is described as follows:

www.w = The present output load, the unit: W

PSP SERIES

USER MANUAL

27

*U

Function:

The maximum voltage limit at present, the unit is V.

Syntax:

U HEX = 55 0D

Explain:

When the message of U is sent to the power supply from
computer, the power supply will return the following message
immediately:

Uuu 3 characters totally + CR/LF

The contents consist of the uppercase U and the numeral from 0 to 9.
Further details is described as follows:

uu = The maximum voltage limit at present, the unit: V

When the uppercase U becoming the lowercase u means that the
power supply is in the setting status of voltage limit mode.

*I

Function:

The maximum current limit at present, the unit is A.

Syntax:

I

HEX = 49 0D

Explain:

When the message of Iis sent to the power supply from computer,
the power supply will return the following message immediately:

Ii.iii

5 characters totally + CR/LF