beautypg.com

Warning, Maintenance – Edwards Signaling 105XBRM User Manual

Page 2

background image

P/N 3101571 ISSUE 3

Figure 2. Securing the Beacon to the Mounting

Attachment

Figure 3. Wiring the 105XBR Series Beacons

Figure 1. Mounting Cat. No. 105BM Mounting Bracket

105-LC Lens

(4) Countersunk screws

to mount lens to 105BM

(supplied)

Gasket

Adhesive backed

gasket

105BM Mounting

Bracket

(4) Screws to mount

105BM to 105BX

(supplied)

Adhesive backed

gasket

(2) Screws to mount

105BX to the

mounting surface

Mounting

Surface

105BX Outlet

Box Attachment

8. Ensuring that the light source is in place, screw the lens

back on the base.

9. Apply power and verify operability.

The lens should be periodically cleaned using a mild deter-

gent and water and a soft, clean, lint-free cloth.

To prevent electrical shock, before starting

work on units disconnect power and, wait 5

minutes for stored energy to dissipate.

WARNING

Maintenance

105-L Series

Lens

105XBR Base

Wire nuts

(not supplied)

DC units; Red Positive (+),

AC units; Black Hot

18” Wire Leads

DC units; Black Negative (-),

AC units; White Neutral

Power Source

Wires

LED Light Source

105-L Series Lens

Beacon Base
Gasket

Adhesive backed

gasket

105PM Pipe Mount

Attachment
3/4" (19 mm) conduit

nipple

OFF

OFF

ON

ON

1

2

Dipswitch

Location