beautypg.com

Wiring diagram for category 4, Ce compliance information general specifications – Edwards Signaling 343-BT User Manual

Page 3

background image

Wiring Diagram for Category 4

Inputs shown with safety gate/guard in closed position. Two Series 300-B GuardSwitches™ with one INT relay are required for each safety gate.

When first applying the INT Safety Monitor Relay, the inputs must be cycled to check for proper operation before the output contacts close. To cycle the inputs, the guard must be
opened and then closed. This start-up test is sufficient; however, we recommend that the proper operation of the switches and relay be checked at least every 24 hours.

*300-BLT-

*Or other DPST GuardSwitch

(See the 300-BT Series

installation instructions)

( – )

( + )

INT-03-230: 230V AC
INT-03-120: 120V AC
INT-03-024: 24V DC

R e q u i r e d F a s t o r
S l o w - A c t i n g F u s e :
( 2 5 0 V , 5 x 2 0 m m F )
I N T - 0 3 - 2 3 0 : 4 0 m A
I N T - 0 3 - 1 2 0 : 8 0 m A
I N T - 0 3 - 0 2 4 : 1 / 4 A

Required Fast or
Slow-Acting
Fuses: 4A (250V,
5x20 mm F

W
H
T

B
L
K

R
E
D

B
L
U

*300-BLT-

W
H
T

B
L
K

R
E
D

B
L
U

Note – The LED on the BLT model

will be ON when the guard is open

Fuses: 1A (250V)

RESET

A

SAFE

AUX.

B

C

D

E

F

G

OUTPUTS

230 VAC

60 VDC

120 VAC

30 VDC

LOADS

+

L1

L2

1

2

X1 X2

Y1

Y2

N.O.

N.C.

Safety Monitor Relay
INT-03

These switches are TUV certified for CE applications only when used with the INT
Safety Monitor Relays. See Risk Category 3 and Category 4 wiring diagrams above.

CE Compliance Information

General Specifications

Enclosure

Kynar

®

, Polyvinylidene Fluoride

Temperature Range

14

°

F to 150

°

F (-10

°

C to 65

°

C)

Environmental

Hermetically Sealed Contact Switch

Encapsulated in Polyurethane

NEMA Rating

1, 2, 4, 4X, 5, 12, 12K, 13

Protection Class

IP 67

Response Time

1 msec

Individual circuits

The two circuits do not switch simultaneously, and depend

on the speed of the guard closure. Based on closure speed

of 1' per second and a gap of 1/8", a delay less than

50 msec is typical.

Life Cycles

100,000 Under Full Load;

Up to 200,000,000 Under Dry Circuit

Lead Types/O.D.

18/4 SJTOW (K)/0.34" (0.86cm)

22/4 PVC Jacketed (J)/0.19" (0.48cm)

22/6 PVC Jacketed (J)/0.21" (0.53cm)

UL/CSA/TUV

All Models

File E 122942

LR89176

European Directives
Machinery Directive (89/392/EEC)
EMC Directive (89/336/EEC)
Low Voltage Directive (73/23/EEC)

Specific European Standards
EN60204-1 Safety of electrical equipment of
industrial machines
EN292 Part 1, 2 Safety of Machinery, basic
terminology, technical principles
EN954-1 Risk Assessment Category 3 or 4 depending
on wiring method, see diagrams
EN55081-2 Electromagnetic Emissions
EN50082-2 Electromagnetic Immunity
EN1088 Interlocking Devices
EN947-5-3 Control Circuit Devices
EN50178 Safety of Electrical Equipment
IEC 664-1 Insulation requirements
IEC 68, part 2-1, 2-2, 2-3, 2-8, 2-14, 2-27, 2-30

Declaration of Conformity

available upon request.

GE Security Industrial

GuardSwitch

TM

Series 300

www.ge-security.com/industrial

This manual is related to the following products: