beautypg.com

Detcon PI-700 User Manual

Page 49

background image

Model PI-700

PI-700 Instruction Manual

Rev. 2.5

Page 45 of 54

Weight:

2 lbs; 0.907kg (sensor only)
6 lbs; 2.72kg (w/aluminum j-box)
9 lbs; 4.08kg (w/stainless steel j-box)

Electrical Specifications

Input Voltage:

11-30 VDC

Power Consumption:

Normal operation = 68mA (<1.7 watt)
Maximum = 85mA (2 watts)

Inrush current:

1.67A @ 24V

RFI/EMI Protection:

Complies with EN61000

Analog Output:

Linear 4-20mA DC current (1000 ohms maximum loop load @ 24VDC)
0mA

All Fault Diagnostics

2mA

In-Calibration

4-20mA

0-100% full-scale

22mA

Over-range condition

Serial Output:

RS-485 Modbus™ RTU

Baud Rate:

9600 BPS (9600,N,8,1 Half Duplex)

Status Indicators:

4-digit LED Display with gas concentration
full-script menu prompts for AutoSpan,
Set-up Options, and Fault Reporting

Faults Monitored:

Loop, Input Voltage,
Zero, Missing Sensor,
Processor, Memory, Calibration

Cable Requirements:

Power/Analog: 3-wire shielded cable

Maximum distance is 13,300 feet with 14 AWG

Serial Output: 2-wire twisted-pair shielded cable specified for RS-485 use

Maximum distance is 4,000 feet to last sensor

I/O Protection:

Over-Voltage, Miss-wiring, EMI/RFI Immunity