beautypg.com

Appendix, Specifications, 1 specifications – Detcon PI-700 User Manual

Page 48

background image

Model PI-700

PI-700 Instruction Manual

Rev. 2.5

Page 44 of 54

9. Appendix

9.1 Specifications

System Specifications

Sensor Type:

Continuous diffusion/adsorption type
Photo Ionization Detector - PID
Plug-in Replaceable Intelligent Type (with replaceable Lamp)

Sensor Life:

2 years typical

Measuring Ranges:

Gas Dependent, ranges as low as 0-10ppm or as high as 0-5,000ppm
(Consult Detcon) Special Low Range 0-500ppb

Accuracy/ Repeatability:

±10% of reading of full-range or ±2% of range (greater of)

Response Time:

T50 <30 seconds; T90 < 60 seconds

Outputs:

Linear 4-20mA DC
RS-485 Modbus™ RTU

Electrical Classification:

Explosion Proof

CSA and US (NRTL)

Class I, Division 1, Groups B, C, D (Tamb=-40° to 75°C)
Class I, Zone I, Group IIB+H2

ATEX

EEx d IIB+H

2

T4 (Tamb=-40° tp 75°C)

Ingress Protection:

NEMA 4X, IP66

Safety Approvals:

cCSAus Performance to ISA 12.13.01-2000 and CSA 22.2 #152
ATEX
CE Marking

Warranty:

Plug-in detector – 1 year
Transmitter – 2 years

Environmental Specifications

Operating Temperature:

-4°F to +122°F; -20°C to +50°C
(Special -40°C version available)

Storage Temperature:

--4°F to +122°F; -20°C to +50°C

Operating Humidity:

0-100% RH Non-Condensing

Mechanical Specifications

Dimensions

7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only)
11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box)
Mounting holes (J-box) 5.5"; 140mm center to center