When installing an ATM, some general environmental and power precau-
tions need to be considered. Evaluate the location where the ATM will be
installed. To help ensure proper operation of the ATM, ensure the environ-
mental criteria listed in this checklist are met.
TEMPERATURE/HUMIDITY
1. The ATM will operate over a range of tempera-
tures and humidity. Generally, these param-
eters must fall within the following ranges:
" Temperature
•
10°C to 40°C
•
50°F to 104°F
" Relative Humidity
•
20% to 80%
•
(Non-Condensing)
AC POWER REQUIREMENTS
2. Ensure the following AC power requirements
are met:
! Power Consumption
•
2.0A @ 115 VAC at 60 Hz
•
1.0A @ 230 VAC at 50 Hz
Dedicated source. The ATM AC power feed will be a
dedicated line, to which no other electrical devices
are connected. The ATM power line will be wired for
a single “duplex”-style outlet and connected directly
to the AC service panel.
Isolated Ground. An equipment grounding conduc-
tor that is insulated from the conduit or raceway and
all other grounding points throughout its entire
length. The only points of electrical connection will
be at the duplex outlet and service panel ends of the
line.
DEDICATED TELEPHONE
3. Ensure the following telephone-line require-
ments are met:
Dedicated line. The telephone line servicing the ATM
will not be a “party” line or any other shared type
connection.
Proximity to Interference Sources. Thetelephone
line must not be in close proximity to “noisy” de-
vices that could induce interference into the ATM
communications channel. See the next section for
additional information on “interference sources.”
RF INTERFERENCE
4. Ensure there are no devices near the terminal
that may cause RF interference, such as:
" TVs
" Coolers
" Security devices
" Neon signs
" Devices with compressors
* IMPORTANT *
AC power for the terminal should come from a
dedicated source with an isolated ground.