Install standard anchors bolt atm to floor – Triton 9100 Installation Manual User Manual
Page 15
15
I
NSTALLATION
P
ROCEDURES
Drill anchor holes
4.
Use a portable vacuum cleaner to remove any dust or debris that may have fallen into the holes during
the drilling process.
3a. Chemical anchors: Use a 15 mm (9/16") diameter carbide-tipped masonry bit to drill four holes at
least 115 mm (4-1/2") deep into the floor. Be sure to take into account the depth of any floor covering,
such as tile or vinyl when gauging the depth of the anchor holes. Make sure the holes are drilled at
least 4- 1/2" (115 mm) into the concrete floor.
Blow out dust/debris.
2
Move the ATM into position for mounting by aligning the base over the four holes drilled in the
previous procedure.
3
Place an anchor bolt through the cabinet base and into one of the mounting holes. Use a ball peen
hammer to tap the bolt completely into the hole.
IMPORTANT: If the anchor bolt “falls” into the hole without needing to be tapped in, the hole is too
large! The mounting-hole pattern will have to be moved and redrilled using smaller holes as
necessary to achieve a snug fit.
1.
Ensure the leveling feet are flush with the bottom of the cabinet. If necessary, use a screwdriver to
adjust the leveling bolts inside the cabinet (near the four corners) so that the leveling feet are flush with
the bottom of the cabinet.
Place anchor bolts in mounting holes.
Tap anchor bolts into mounting holes.
Install Standard Anchors
Bolt ATM to Floor