beautypg.com

Troubleshooting – SnowEx PWX-250 User Manual

Page 17

background image

17

© Trynex International 2012 (REV A) F50766

Troubleshooting

Model # PWX-200 / PWX-250

Warning: First read all warning instructions and safety messages before servicing the Sprayer.

Preliminary checks

• Be sure all electrical connections are tight and clean.
• Be sure nothing is obstructing the nozzles.

PROBLEM

POSSIBLE CAUSE

SOLUTION

Pump doesn’t run.

Loose electrical connections.

Blown fuse.

Pump seized.

Check all connections.

Replace fuse.

Replace pump.

Controller shut down.

Poor electrical connections.

Electrical short.

Controller failure.

Clean or replace connectors.
Use dielectric grease.

Check electrical connections.
Check for bare wires.

Replace controller.

Liquid not spraying.

Empty tank.

Full Strainer.

Pump not running.

Obstructed nozzle.

Fill tank.

Clean or replace filter element.

Refer to Problem 1.

Remove and clean.

This manual is related to the following products: