SANDPIPER M1F Non-Metallic User Manual
Page 34

m1fnmdl3sm-rev0713
Model M1F Non-Metallic Page 32
DUAL PORTING OPTIONS
Several dual porting options are
possible. The pump can be converted
to a dual port arrangement on both
the suction and the discharge ends.
The porting can be configured to a
single suction and a dual discharge.
The porting can be changed to a dual
suction and a single discharge.
The above changes are possible
because the porting flange of the
elbows (items 18 and 19) are designed
to mate with standard 125# ANSI style
4-bolt, 1" pipe flanges.
DUAL PORTING OF BOTH SUCTION
AND DISCHARGE ENDS OF THE
PUMP
Converting the pump from the
standard single suction and discharge
porting configuration to dual porting at
each end is easy. Simply remove the
manifold seals, spacers, and manifolds
(items 35 and 23 from pump assembly
drawing) from the pump.
The discharge and suction elbows
can be rotated at 90° increments (see
arrows and optional positioning in the
Dual Porting Drawing.
SINGLE PORTING OF THE SUCTION
AND DUAL PORTING OF THE PUMP
DISCHARGE
To convert the pump from the
standard single suction and single
discharge porting configuration to a dual
discharge porting arrangement remove
the only the discharge manifolds,
spacers, and manifold seals. Position
the discharge elbows in the desired
direction at 90° increments. (See arrows
and optional positioning in the Dual
Porting Drawing.)
DUAL PORTING OF THE SUCTION
AND SINGLE PORTING OF THE
PUMP DISCHARGE
To convert the pump from the
standard single suction and single
discharge porting configuration to a dual
suction porting arrangement remove
the only the suction (bottom) manifolds,
spacers, and manifold seals.
Position the suction elbows in the
desired direction at 90° increments.
(See arrows and optional positioning
in the Dual Porting Drawing.)
IMPORTANT
Read these instructions
completely, before
installation and start-up.
It is the responsibility
of the purchaser to retain this manual
for reference. Failure to comply with the
recommendations stated in this manual
will damage the pump, and void factory
warranty.