beautypg.com

SANDPIPER M1F Non-Metallic User Manual

Page 34

background image

m1fnmdl3sm-rev0713

Model M1F Non-Metallic Page 32

DUAL PORTING OPTIONS

Several dual porting options are

possible. The pump can be converted

to a dual port arrangement on both

the suction and the discharge ends.

The porting can be configured to a

single suction and a dual discharge.

The porting can be changed to a dual

suction and a single discharge.

The above changes are possible

because the porting flange of the

elbows (items 18 and 19) are designed

to mate with standard 125# ANSI style

4-bolt, 1" pipe flanges.

DUAL PORTING OF BOTH SUCTION

AND DISCHARGE ENDS OF THE

PUMP

Converting the pump from the

standard single suction and discharge

porting configuration to dual porting at

each end is easy. Simply remove the

manifold seals, spacers, and manifolds

(items 35 and 23 from pump assembly

drawing) from the pump.

The discharge and suction elbows

can be rotated at 90° increments (see

arrows and optional positioning in the

Dual Porting Drawing.

SINGLE PORTING OF THE SUCTION

AND DUAL PORTING OF THE PUMP

DISCHARGE

To convert the pump from the

standard single suction and single

discharge porting configuration to a dual

discharge porting arrangement remove

the only the discharge manifolds,

spacers, and manifold seals. Position

the discharge elbows in the desired

direction at 90° increments. (See arrows

and optional positioning in the Dual

Porting Drawing.)

DUAL PORTING OF THE SUCTION

AND SINGLE PORTING OF THE

PUMP DISCHARGE

To convert the pump from the

standard single suction and single

discharge porting configuration to a dual

suction porting arrangement remove

the only the suction (bottom) manifolds,

spacers, and manifold seals.

Position the suction elbows in the

desired direction at 90° increments.

(See arrows and optional positioning

in the Dual Porting Drawing.)

IMPORTANT

Read these instructions

completely, before

installation and start-up.

It is the responsibility

of the purchaser to retain this manual

for reference. Failure to comply with the

recommendations stated in this manual

will damage the pump, and void factory

warranty.

IMPORTANT