2 5
7.1 Feed
Level
When the Feed Level indicator is ON,
the Main Display will show the
amount of feed remaining in the
specific feed bin. The Feed Level is
shown in number of feet or meters
from the feed bin’s boot. The unit of
measure (Feet or Meters) can be set in
the Program P1 setting (Refer to
Section 6.1). View the Feed Level by
pressing the specific required Bin
Selection Button (1, 2, 3, or 4). The
specific Feed Bin Level Indicators
will repeatedly flash to indicate the
selected feed bin.
7.2
Feed Capacity (%)
When the Feed Capacity indicator is
ON, the Main Display will show the
percentage of feed remaining in the
specific feed bin. View the Feed
Capacity by first pressing the
specific required Bin Selection
Button (1, 2, 3, or 4). The specific
Feed Bin Level Indicators will
repeatedly flash to indicate the
selected feed bin. Next, press the
Mode select button once until the
Feed Capacity indicator turns ON.
7.3 Bin
Status
The selectable Bin Status is used to
turn a specific feed bin’s alarm either
ON or OFF. The feed Bin Status can
be turned OFF (Minus – button) to
disable the Minimum Feed Capacity
alarm and prevent this alarm from
reoccurring until the Bin Status is
manually turned ON (Plus + button).
To view or change the Bin Status,
first press the specific required Bin
Selection Button (1, 2, 3, or 4). The
specific Feed Bin Level Indicators
will repeatedly flash to indicate the
selected feed bin. Next, press the
Mode select button twice until the
Bin Status indicator turns ON. The
Main Display will show the
selectable Bin Status of the specific
feed bin.
Feed Level
5.3
Feed Capacity
Bin Status