Hired-hand manufacturing., inc – Hired-Hand Evolution Series 3000/3001: Add-On Ventilation Kits User Manual
Page 11

Hired-Hand Manufacturing., Inc.
• 1733 Co Rd 68 • Bremen, Alabama 35033 • Phone 256-287-1000 • Fax 256-287-2000
Manual Part No. 4801-5308 rev 09-05
Page 11 of 12
Figure 6: Connecting the PowerTrak to the Tunnel Aux. Input for the
2-Stage Inlet
Close
Aux.
+12V
+12V
Com.
Auxilliary Inputs
Relay Control
Tunnel Aux. Input Vent Aux. Input
Relay Control
Variable Module
HHNet Termination
Power Ventilation Module
Natural Ventilation Module
Var #1
Var #2
Open
U1
Open
U1
Open
U2
Open
U2
Open
AUX
Close
AUX
Open
AUX Com
Close
AUX
Com
Com.
Close
Aux.
Close
U1
Close
U1
Close
U2
Close
U2
+
+
-
-
+12V
GND Shield
Local Network
-
Sensor #1
Te
m
pe
ra
tu
re
Se
ns
or
s
Te
m
pe
ra
tu
re
S
en
so
rs
Black
Black
Black
Black
Black
Black
Black
Black
Black
White
Shield
White
Shield
White
Shield
White
Shield
White
Shield
White
Shield
White
Shield
White
Shield
White
Shield
Sensor #2 Sensor #3 Sensor #4 Sensor #5 Sensor #6 Sensor #7
Sensor #8
Outside
N.C.
IN
N.C.
OUT
N.O.
IN
N.O.
OUT
Auxilliary Alarm
DC Power Supply
+12V +5V
11
5
V
23
0 V
AC Supply
L1
L2
PCB 169
Inset A
Inset B
NOTE: If the curtain is setup to pull curtain up to open, then reverse wires connected
to ‘OPEN’ and ‘CLOSE’.
- Polar Cool: Portable Evaporative Cooling System (22 pages)
- Polar Cool: External Control Box (4 pages)
- Polar Cool: Pump & Float Replacement (2 pages)
- Polar Cool: PUMP REPLACEMENT (4 pages)
- Polar Cool: Wall Mount Kit (4 pages)
- Unitized Mega Cool (68 pages)
- Unitized Mega Cool: Square Bottom (63 pages)
- Mega-Cool: Square Reservoir (24 pages)
- Mega-Cool rev 6-09 (46 pages)
- Mega-Cool: Mega-Cool Pad Extender Kit (5 pages)
- Mega-Cool: Float Valve Replacement (1 page)
- Mega-Cool: Float Valve (Topaz) Replacement (1 page)
- Mega-Cool: In-Line Pump Motor Replacement (2 pages)
- Var-O-Matic (2 pages)
- System 1000 Power Vent (31 pages)
- System 1000 Power Vent (13 pages)
- System 500 Programs (Conventional Model) (5 pages)
- System 100 Variable Speed Controller (7 pages)
- System 500 Programs (Tunnel Model) (7 pages)
- System 1000 Power Curtain (17 pages)
- System 2000 AUTO TEMP (10 pages)
- System 2001 Power Curtain Controller (43 pages)
- System 500 Power Curtain Controller (31 pages)
- System 1000 Power Curtain Eight Stage Controller (34 pages)
- ICS-500 Environmental Controller (34 pages)
- Pressure Transducer Changeout (1 page)
- HH Software: HH.Net Router/Repeater (8 pages)
- HH Software: 900SS Wireless Network (10 pages)
- HH Software: Farm Manager (22 pages)
- HH Software: Data Shuttle Launch Pad (25 pages)
- Sens-O-Matic (Feed Hopper Switch) (2 pages)
- Manual Light Dimmer (2 pages)
- Electro Mechanical Controls (Relay-Switches): PHOTOHELIC POWER VENT (10 pages)
- Electro Mechanical Controls (Relay-Switches): PT Controller (9 pages)
- Electro Mechanical Controls (Relay-Switches): PC-DB Curtain Controller with DIF (6 pages)
- Electro Mechanical Controls (Relay-Switches): PC-DB Curtain Controller with Timer Override (7 pages)
- Electro Mechanical Controls (Relay-Switches): Photohelic Gauge (1 page)
- Feed Management System (15 pages)
- Contactor Control System (CCS): 4, 8, or 12 Stage (19 pages)
- Contactor Control System (CCS): Triple Pole 16-Stage (7 pages)
- Contactor Control System (CCS): Vent Machine Override 3 Wire PowerTrak (1 page)
- Evolution 4000 Control System (86 pages)
- Evolution Series 1200: Variable Output With Override Pot (14 pages)
- Evolution Series 1200: Variable Output (12 pages)
- Evolution Series 1200 (64 pages)