5.1.2 Outside Temperature

The temperature read by the sensor located outside the house. (Sensor 3)









5.1.3 Var/Timer Percentage

This is the percentage of the timer cycle that a stage on a timer will run. If this is set for
30, and your timer period is set to 10 Minutes, the timed stages will run for 3 minutes out
of every ten minutes. This setting will also show minimum speed settings for variable
speed fans on controllers with that option.
When you are stepping through the main display parameters and you get to this option,
be sure to notice the stage status indicators. This parameter may be different for each
variable speed/Cool Timer stage. As you press the Mode button, the Var/Timer
Percentage display will show each of the settings. If the Var/Timer Percentage LED on
the main display is lit, and the stage status indicator beside Variable Speed Stage 1 is lit,
any adjustment to the setting will only affect that particular stage.
Refer to Section 6.2 "Variable/Cool Timer" for programming information.

Minimum Speed for Variable Stage 1

To view or change the Minimum Speed for Variable Stage 1, press the Mode button until
the Var/Timer Pct Indicator initially turns ON. At this point, the Green Var/Timer Pct
Indicator will be ON and the Variable Stage “1” Red Indicator will be ON solid (not
flashing) and the current Minimum Speed for Variable Stage 1 will be shown in the
Display. The “+” button will increase or the “-“ button will decrease the Minimum
Speed only for Variable Stage 1.





















3 0

Variable Stage 1 Minimum Speed

1

Mode Button

Variable Stage 1

Status Indicator

Var/Timer Pct
Indicator

+ Button

(Increases Var/Timer Pct)

- Button

(Decreases Var/Timer Pct)

9 6. 8

Outside Temperature

Outside Temp Indicator