10. Maintenance

Check the calibration of your sensors at least once per quarter. To do this, you will need to have two
persons. One person should be at the sensor with a trusted thermometer, and another person at the
controller to set the sensor to the proper setting.

11. Wiring Diagrams

All wiring connections for stages, curtain machines, variable speed fans, and curtain sensors inside the
controller are provided with removable terminal blocks to attach to the end of the wire. To make the
connection, strip about ¼” of the insulation off the wire, remove terminal block from PCB 164, insert wires
into appropriate terminal block slots, and tighten the set-screws securely by hand.

Warning!

Do not connect more than twelve (12) amps of load to any one stage.