6.5 Cool Timer Settings

The following two settings allow the user to set the Runtime range for their cool timer stages.

P70 = Cool Timer Maximum Percentage
This sets the maximum Runtime percentage that a cool timer stage can operate.

P71 = Cool Timer Minimum Percentage
This sets the minimum Runtime percentage that a cool timer stage can operate.

6.6 Sensor Calibration

The SC-5v2 has 3 sensors that may be calibrated. The parameter(s) for calibration are PSx with x
being the sensor number. The sensor temperature reading is alternately displayed along with the
parameter number.
You should never attempt to calibrate a sensor more than 8 degrees. If you have a setting that far
out of range, it indicates that there is a problem that should be corrected.

PS1 - Calibrate Sensor 1

This reading can be changed by pressing the + or - button until the desired
reading is displayed.

PS2 - Calibrate Sensor 2

This reading can be changed by pressing the + or - button until the desired
reading is displayed.

PS3 - Calibrate Sensor 3

This reading can be changed by pressing the + or - button until the desired
reading is displayed.