Hired-Hand Farm Hand Series: SC-5v2 User Manual
Page 36
![background image](/manuals/362896/36/background.png)
Part No. 4801-5324 Rev 9-05
Farm Hand SC-5v2 5 Stage
36 of 40
12.4 Status Switches Reference
Status Switches (Located inside the Controller Door)
SWX 1 - Lock
Locks the front panel to protect your settings from accidental
change. If the switch is set to ON the program settings are
locked.
SWX 2 - Fahrenheit or
Celsius
Switches the temperature readings from Fahrenheit to Celsius.
If the switch is set to ON the controller will read the sensors as
Fahrenheit. (Note: If you change this switch, you will have to
reset your tunnel on points and off points and your Target
Temperature.)
SWX 3 - 5/10 minute timer
This switch selects between a 5 and 10 minute system timer. If
the switch is on, the timer is 10 minutes.
SWX 4 - Curtains On
Separate Sensor
This switch is used to choose whether the curtain machines
operate off the same sensor or if they operate independently. If
the switch is on, the curtains are independent with curtain 1
running on sensor 1, and curtain 2 running on sensor 2.
SWX 5 - Tunnel On/Off
Enables/Disables tunnel mode When this switch is in the off
position, the controller will not go into tunnel for any reason.
SWX 6 - Tunnel On Stage
Option to have the controller go into tunnel whenever the first
tunnel stage turns on. If this switch is off, the controller will
use the “Tunnel On Point” setting for entry into tunnel.
SWX 7 - Power Ventilate
If you have a power ventilated house the controller will leave
the inlet curtain closed until tunnel mode is entered.
This switch must be set to “on” if you have a Power Ventilated
house.
SWX 8 - Program ‘A’ or ‘B’
This switch is used to toggle between 2 preset programs. This
could be used to store separate summer/winter programs for
instance. The ON position is for Program A, and the OFF
position is for Program B.