beautypg.com

Hired-Hand Farm Hand Series: SC-5v2 User Manual

Page 7

background image

Part No. 4801-5324 Rev 9-05

Farm Hand SC-5v2 5 Stage

7 of 40

Control Buttons (Mode, +, & -)

Just below the main display on the right hand side of the controller is the control button region. This
region has three buttons, Mode, +, and -. You will learn the use of these three buttons later in the
manual.

Program Parameters

Just below the Stage Status Indicators on the left hand side of the controller is the Program Parameters
Quick-Reference information. This information provides a helpful quick-reference to the various
programming options.

Manual Switch Override

Just below the control buttons on the right hand side of the controller is the Natural Ventilation
Controls section for two separate curtain machines (Unit 1 and Unit 2). This section contains toggle
switches to provide curtain machine manual switch override capability. The Auto/Manual toggle
switches determine if the curtain machines are in automatic or manual override operation mode. When
the Auto/Manual switch is in the Manual position, the Open/Off/Close 3-position toggle switch allows
the user to manually turn the curtain machine to Open, Off, or Close for each machine.

5. Day to Day Operating Instructions

This section of the manual will give you all you need to know about the day to day operation of your
controller.

5.1 Checking/Adjusting Temperatures and Timer Percentages

At any time you want to see the average temperature of your house, just look at the display.
When no one has pressed a button for over one minute, the display will automatically show
“Room Temperature”. To see the outside temperature, press the button labeled “Mode”. This
button is located in the center of the controller facepad. When you press the button, watch the
green indicator beside the main display. Whichever indicator is lit is the parameter you are
viewing. You can easily see “Outside Temperature”, “Var/Timer Percentage”, and “Target
Temperature”.

5.1.1 Room Temperature

The average of the sensors located inside the house.











7 4. 3

Average Room Temperature

Room Temp Indicator