Hired-Hand Farm Hand Series: SC-5v2 User Manual
Page 35
Part No. 4801-5324 Rev 9-05
Farm Hand SC-5v2 5 Stage
35 of 40
P22 -- Initial Run Time
Number of seconds to run on the first drop from closed. This is
to be sure that you have cleared the top of the opening. This
setting only applies when the controller senses that the curtain
is closed when it begins its run.
P23 -- Degrees above
target (Unit 1)
Many times it is more cost effective to bring a slightly high
temperature back into range with a fan. This setting allows you
to specify a number of degrees above the target temperature
that the curtain will allow before trying to open.
P24 -- Degrees above
target (Unit 2)
Occasionally, a grower may want one curtain sidewall to drop
before the other to try to avoid large temperature swings. This
setting allows for this to happen. Note: If you would like
both curtain units to always react together, you must set
P23=P24.
P25 – Tunnel Onpoint
This is the sensor 3 temperature at which the controller will
enter tunnel mode. Only applicable when tunneling on outside
temperature.
P26 -- Tunnel Offpoint
This is the sensor 3 temperature at which the controller will
enter tunnel mode. Only applicable when tunneling on outside
temperature.
P27 -- Close Override
The degrees below target at which time the curtains will
override to close.
P40 - HHNet Address
Unique setting for controllers along a single network wire pair.
Only used with the PC compatibility feature using Hired-
Hand’s Farm Manager software.
P41 -- Version Number
This is the version of the software for the controller. This value
is not settable.
P42 -- Controller Type
This is a number that identifies the type of controller (Swine
Finisher) to the Farm Manager Software (PC compatible)
PS1 - Calibrate Sensor 1
The temperature the controller reads from Sensor 1. This
setting is used only when calibrating sensors. Press the +
and/or - buttons until the correct reading is seen in the main
display. (See Sensor Calibration)
PS2 - Calibrate Sensor 2
The temperature the controller reads from Sensor 2. This
setting is used only when calibrating sensors. Press the +
and/or - buttons until the correct reading is seen in the main
display. (See Sensor Calibration)
PS3 - Calibrate Sensor 3
The temperature the controller reads from Sensor 3. This
setting is used only when calibrating sensors. Press the +
and/or - buttons until the correct reading is seen in the main
display. (See Sensor Calibration)