Part No. 4801-0165 Rev 7-02

Data Shuttle Launch Pad

7

Saves the data to
a file.

Opens a
file.

Return to
title
window.

This Option only
appears on Vents
with Ramping.

Return to
External
Functions
window.

Load / Save Default – A single schedule can be saved as a default schedule and recalled
with these buttons.

9. Programming the Data Shuttle to Load Farm Hand Controller Settings

This section describes the various windows required to load controller settings into the Farm Hand
Power Vent, Stage controllers and the Alert Alarm. The Data Shuttle can be loaded with settings
for each type of controller. When the Data Shuttle is connected to a controller, the Shuttle
recognizes the specific type of controller and sends the appropriate settings.
Before using the Launch Pas software to load controller settings, the user should become familiar
with the controllers by reading the appropriate controller user manual. These manuals are listed in
the reference section of this document in Section 9.

For the Farm Hand power vent controllers there are three windows: a GENERAL, a RAMPING
and an ALARM. To program the Farm Hand stage controllers there are up to four windows
depending upon the specific controller: a GENERAL, a STAGE DATA, a VARIABLE SPEED
and a CURTAIN. The Vent Master uses a GENERAL, a STAGE DATA, an INLETS, a
RAMPING and an ALARM. To program the Alert Alarm there are three windows: a STATUS,
a TEMPERATURE and a WATER.

The following sections discuss the various programming windows. After programming the
desired parameters, it is necessary to return to the GENERAL window for stage controllers and the
STATUS window for the Alert Alarm and select the OK button to return to the Data Shuttle
External Functions window to launch the Shuttle.

10. Programming Farm Hand Power Vent Controllers

10.1 GENERAL Window

This window applies to Î Farm Hand Power Vent

Î Farm Hand Power Vent with Ramping

This window is selected by clicking on the General tab at the top
of the window.

This window allows the Power Vent Static Pressure to be
adjusted. Also, the High and Low
Pressure Limits
and Vent Time
Delay
can be set. A check box is
provided to either enable or disable
the use of Ramped Values, which
are set in the Ramping window.

The Program Loader allows the
reading and saving of Power Vent
settings into files which can be
recalled for later use. Vent settings
that are frequently used can be
easily retrieved, modified and
transferred to the appropriate Farm
Hand controller. To retrieve a file,
double click on the file name.

The Save and Open options are
used with this feature. In the
example below, a file
called Summer.dsp
contains previously
loaded power vent
settings.